installation
Offset to Vertical Terminations
Venting Arrangements - Horizontal Terminations using Dura-Vent venting system
and/or Riser Vent Termination
Snorkel Termination
Riser Vent Termination
Venting Arrangements
Vertical Terminations Systems for
Residential Manufactured and Mobile Homes
The shaded area in the diagram below shows all allowable combinations of straight
vertical and offset to vertical runs with vertical terminations.Maximum two 45
o
elbows.
IftheventisENCLOSEDinachase(min.size9"x9")maintaina1-1/4"clearanceto
combustibles.
May be installed in Manufactured (Mobile) Homes after first sale.
Horizontal Terminations for
All Venting Systems
The shaded areas in the diagram below show all al-
lowable combinations of vertical runs with horizontal
terminations.Maximumone90
O
elbow(two45
o
elbows
equalone90
o
elbow).
Propane and Natural Gas:
Residential, Manufactured and Mobile
Homes Installations
May be installed in Manufactured (Mobile) Homes
after first sale.
The two diagrams show all allowable com-
binations of straight horizontal termination
with one 45
o
elbow off the unit with Snorkels
or FPI Riser Vent. Restrictor position "A".
Содержание H27
Страница 51: ...Hampton H27E 11 Direct Vent Freestanding Gas Stove 51 notes...
Страница 56: ...56 Hampton H27E 11 Direct Vent Freestanding Gas Stove warranty...
Страница 57: ...Hampton H27E 11 Direct Vent Freestanding Gas Stove 57 notes...
Страница 58: ...58 Hampton H27E 11 Direct Vent Freestanding Gas Stove notes 58...
Страница 59: ...Hampton H27E 11 Direct Vent Freestanding Gas Stove 59...