![HAMPTON BAY H27 Скачать руководство пользователя страница 14](http://html2.mh-extra.com/html/hampton-bay/h27/h27_owners-and-installation-manual_3533461014.webp)
14
|
Hampton
®
H27E-11DirectVentFreestandingGasStove
installation
1) Provide adequate clearances for servicing,
properoperationandaroundtheairopenings
intothecombustionchamber.
2) Theappliancemustbeinstalledonaflat,solid,
continuoussurface(e.g.wood,metal,concrete).
Thismaybethefloor,oritcanberaisedup
onaplatformtoenhanceitsvisualimpact.The
appliancemaybeinstalledoncarpeting,tile,
wood flooring or other combustible material,
becausetheappliance'sbaseextendsthefull
widthanddepthoftheappliance.TheDirect
VentFreestandingGasStovecanbeinstalled
inawidevarietyofwaysandwillfitnearlyany
roomlayout.Itmaybeinstalledinarecessed
position,framedoutintotheroom,oracross
acorner.
3) TheDirectVentFreestandingGasStoveis
approvedforalcoveinstallations,whichmeet
theclearanceslistedoninthe"Clearanceto
Combustibles"section.Thisunitisapproved
for manufactured home installations, see
the "Manufactured Mobile Home Additional
Requirements"sectionand"VentingArrange-
ments"sectionfortherequiredventarrange-
ments.Ifinstalledintoamanufacturedhome
theunitmustbebolteddowntothefloor.
4) ThisapplianceisListedforbedroominstal-
lationswhenusedwithaListedMillivoltTher-
mostat.Someareasmayhavefurtherrequire-
ments,checklocalcodesbeforeinstallation.
5) ThisapplianceisListedforAlcoveinstallations,
maintainminimumAlcoveclearancesasfollows,
minimumwidthof34-3/4"(882mm),amaximum
depth of 36" (914mm), and minimum ceiling
heightof51"(1295mm)fromfloortoceiling.
6) Werecommendthatyouplanyourinstallationon
paperusingexactmeasurementsforclearances
andfloorprotectionbeforeactuallyinstallingthis
appliance.Haveaqualifiedbuildinginspector
reviewyourplansbeforeinstallation.
General Safety
Information
1) Theapplianceinstallationmustconformwith
localCanadianElectricalCode.
2) Theappliancewheninstalled,mustbeelectri-
callygroundedinaccordancewithlocalcodes,
orintheabsenceoflocalcodeswiththecurrent
NationalElectricalCode,ANSI/NFPA70orCSA
C22.1CanadianElectricalCode.
3) Theapplianceshouldbeinspectedforshipping
damagebeforeuseand
serviced annually by
a professional service person.Morefrequent
cleaning may be required due to excessive
lint from carpeting, bedding material, etc. It
isimperativethatcontrolcompartments,and
circulatingairpassagewaysoftheappliance
bekeptcleanandfreefromexcessivelintfrom
carpeting.
4) See general construction and assembly in-
structions.Theapplianceandventshouldbe
enclosedwheninstalledinorpassingthrougha
livingarea,wherechildrenmaycomeincontact
withit.
5) Thisappliancemustbeconnectedtothespeci-
fiedventandterminationcaptotheoutsideof
thebuildingenvelope.Neverventtoanother
roomorinsideabuilding.Makesurethatthe
ventisfittedaspertheinstructionsstartingin
the"ExteriorVentTerminalLocations"section.
6) Inspecttheventingsystemannuallyforblock-
ageandanysignsofdeterioration.
7) Ventingterminalsshallnotberecessedintoa
wallorsiding.
8) Anysafetyglassremovedforservicingmust
bereplacedpriortooperatingtheappliance.
9) Topreventinjury,donotallowanyonewhois
unfamiliarwiththeoperationtousethefireplace.
Installation
Checklist
1) Locateyourappliance.Refertothefollowing
sections:
a.ClearancestoCombustibles
b.LocatingYourGasStove
c."VentingIintroduction"to"ExteriorVent
TerminalLocations"sections..
2) InstallOptionalFan.Refertothe"OptionalFan
Installation"section.
3) Setventrestrictor.Refertothe
"VentRestrictorPosition"section.
4) Installventing:Checkallventingrequirements.
See"VentIntroduction"to"Dura-VentVertical
Termination"sections.
5) Makegasconnections.Refertothe"GasCon-
nection"section.
IfconvertingtoPropane,makechangesprior.
Refertothe"ConversionfromNaturalGasto
Propane"section.
6) Install3AAAbatteriesintoRemotetransmitter
andpairitwithIFCboard(seeRemoteControl
section).
7) TestGasPressure.Refertothe"PressureTest-
ing"section.
8) Installstandardandoptionalfeatures.Referto
thefollowingsectionswhereapplicable:
a.LogSetInstallation
b.WallThermostat
c.RemoteControl
d.AccentLightBulbInstallation
e.FanInstallation
9) Finalcheck.Refertothe"FinalCheck"section.
Before leaving this unit with the customer, the
installermustensurethattheapplianceisfiringcor-
rectlyand
operation fully explained to customer.
This includes:
1) Clockingtheappliancetoensurethecorrect
firing rate (rate noted on label) after burning
appliancefor15minutes.
2) Ifrequired,adjustingtheprimaryairtoensure
thattheflamedoesnotcarbon.Firstallowthe
unittoburnfor15-20min.tostabilize.
CAUTION: Any alteration to the product that
causes sooting or carboning that results in dam-
age is not the responsibility of the manufacturer.
Содержание H27
Страница 51: ...Hampton H27E 11 Direct Vent Freestanding Gas Stove 51 notes...
Страница 56: ...56 Hampton H27E 11 Direct Vent Freestanding Gas Stove warranty...
Страница 57: ...Hampton H27E 11 Direct Vent Freestanding Gas Stove 57 notes...
Страница 58: ...58 Hampton H27E 11 Direct Vent Freestanding Gas Stove notes 58...
Страница 59: ...Hampton H27E 11 Direct Vent Freestanding Gas Stove 59...