27
Installing FRUs
There is no required order for installing FRUs. As a best practice, connect power cords after you complete
installing all required FRUs.
TIP:
Keep the chassis and the component packages for future use.
Attaching an ESD wrist strap
An ESD wrist strap is provided with the switch. To minimize ESD damage to electronic components, wear
the ESD wrist strap and make sure it is reliably grounded when installing FRUs.
To attach an ESD wrist strap:
1.
Make sure the switch is reliably grounded. For information about how to ground your switch, see
"
."
2.
Put on the wrist strap.
3.
Tighten the wrist strap to keep good skin contact. Make sure the resistance reading between your
body and the ground is between 1 and 10 megohms.
4.
As shown in
, insert the ESD wrist strap into an ESD jack (one on the front panel and the
other on the rear panel) on the switch chassis.
Содержание S12500-X
Страница 35: ...26 Figure 20 Grounding the switch through the RTN wire of the DC power module...
Страница 80: ...71 Figure 51 Replacing an LPU 1 1 Loosen the captive screw 2 Pull the ejector levers outward...
Страница 138: ...129 Figure 75 CXP fiber cable 1 Connector 2 Pull latch 1 2...
Страница 152: ...143 Figure 91 Cable routing from the left side for an S12510 X AC S12510 X DC switch...