120
Figure 65
Power module LEDs
(1) Power input LED
(2) Power output LED
(3) Over-temperature alarm LED
(4) Fault LED
Table 67
Power module LED description
Power input
LED (green)
Power output
LED (green)
Over-temperature
alarm LED (yellow)
Fault LED
(red)
Description
Steady on
Steady on
Off
Off
The power module is operating
correctly.
Steady on
Steady on
Steady on
Off
An over-temperature alarm has
occurred.
Steady on
Off
Steady on
Steady on
The power module is powered off
because of over-temperature.
Flashing Off
Off
Off
The power input has exceeded or
dropped below the threshold.
Steady on
Off
Off
Steady on
The power module is powered off
because of overvoltage.
Steady on
Flashing
Off
Off
The power output is overloaded.
Off
Off
Off
Off
No power is being input.
Steady on
Steady on/Off Off
Steady on
Unidentified power module
faults.
Содержание S12500-X
Страница 35: ...26 Figure 20 Grounding the switch through the RTN wire of the DC power module...
Страница 80: ...71 Figure 51 Replacing an LPU 1 1 Loosen the captive screw 2 Pull the ejector levers outward...
Страница 138: ...129 Figure 75 CXP fiber cable 1 Connector 2 Pull latch 1 2...
Страница 152: ...143 Figure 91 Cable routing from the left side for an S12510 X AC S12510 X DC switch...