87
Section Description Remarks
(6) MPU slots
Both MPUs and MPU slots are pink
edged for easy identification.
No MPUs are shipped with the chassis.
Two MPU slots are available on an S12500-X
switch. One MPU can meet the operation
requirements of the switch. For redundancy,
you can install two MPUs.
You can install an MPU in either empty MPU
slot.
(7) Power
receptacles
•
Located in the power distribution
box area at the lower part of the
rear panel.
•
Receptacle numbers are marked
above or below the receptacles.
An S12510-X AC/S12510-X DC switch
provides eight power module slots: PWR1 to
PWR8.
An S12516-X AC/S12516-X DC switch
provides 12 power module slots on two power
distribution boxes. Each box has six power
module slots numbered PWR1 to PWR6.
Choose power receptacles according to the
slot numbers of the power modules that have
been installed.
describes the slot arrangement for FRUs.
Table 15
Slot arrangement for FRUs
Switch model
MPU
Switchin
g fabric
module
LPU
PWR
Fan tray
•
S12510-X AC
•
S12510-X DC
Slots 16
and 17
Slots 10
to 15
Slots 0 to
9
PWR 1 to PWR 8
FAN 1 and
FAN 2
•
S12516-X AC
•
S12516-X DC
Slots 16
and 17
Slots 18
to 23
Slots 0 to
15
Two power distribution boxes,
each having six power module
slots numbered PWR1 to PWR6.
FAN 1 and
FAN 2
Weights and dimensions
Table 16
Chassis weights and dimensions
Model Weight Height
Width
Depth
S12510-X AC
85 kg (187.39 lb)
930 mm (36.61
in)/21 RU
440 mm (17.32
in)
830 mm (32.68
in)
S12510-X DC
88 kg (194.00 lb)
930 mm (36.61
in)/21 RU
440 mm (17.32
in)
830 mm (32.68
in)
S12516-X AC
74 kg (163.14 lb)
1018 mm (40.08
in)/23 RU
440 mm (17.32
in)
830 mm (32.68
in)
S12516-X DC
76 kg (167.55 lb)
1018 mm (40.08
in)/23 RU
440 mm (17.32
in)
830 mm (32.68
in)
Rack height is measured in RUs. One RU is 44.45 mm (1.75 in).
Содержание S12500-X
Страница 35: ...26 Figure 20 Grounding the switch through the RTN wire of the DC power module...
Страница 80: ...71 Figure 51 Replacing an LPU 1 1 Loosen the captive screw 2 Pull the ejector levers outward...
Страница 138: ...129 Figure 75 CXP fiber cable 1 Connector 2 Pull latch 1 2...
Страница 152: ...143 Figure 91 Cable routing from the left side for an S12510 X AC S12510 X DC switch...