119
LED status
Description
Off
No link is present.
Switching fabric module LEDs
The switching fabric module has one RUN LED and one ALM LED to indicate its operating status.
Table 65
Switching fabric module LED description
RUN LED
ALM LED
Description
Flashing (once
every two seconds) Off
The switching fabric module is operating correctly.
Off
Steady on
The switching fabric module is faulty.
Flashing (once
every two seconds) Steady on
The switching fabric module is loading software or not operating
correctly. For example, the temperature of the switching fabric
module has exceeded the upper or lower limit.
Off
Off
The switching fabric module has not started or not powered on.
Steady on
Steady on
The switching fabric module is starting up.
Fan tray status LEDs
The fan trays for the S12500-X switches have one OK LED and one FAIL LED to indicate its operating
status.
Table 66
Fan tray LED description
OK FAIL Description
On
Off
The fan tray is operating correctly.
Off
On
The fan tray is faulty.
Off
Off
The fan tray is not powered on.
Power module LEDs
The power modules available for the S12500-X switch have four LEDs to indicate its operating status.
To view the power module LEDs, you must remove the plastic panel. For more information, see
"
."
Содержание S12500-X
Страница 35: ...26 Figure 20 Grounding the switch through the RTN wire of the DC power module...
Страница 80: ...71 Figure 51 Replacing an LPU 1 1 Loosen the captive screw 2 Pull the ejector levers outward...
Страница 138: ...129 Figure 75 CXP fiber cable 1 Connector 2 Pull latch 1 2...
Страница 152: ...143 Figure 91 Cable routing from the left side for an S12510 X AC S12510 X DC switch...