70
Replacing an MPU or LPU
The replacement procedures of an MPU are the same as those of an LPU. The following illustrates the
replacement of an LPU.
To replace an LPU:
1.
Prepare an antistatic mat to place the removed LPU.
2.
Wear an ESD wrist strap, and make sure it makes good skin contact and is reliably grounded. For
more information, see "
3.
Use a Phillips screwdriver to loosen the captive screw on the LPU, as shown in callout 1 on
.
4.
Move the ejector levers outward to separate the LPU from the backplane, as shown in callout 2
on
.
5.
Use one hand to slowly move the LPU outward. Supporting the bottom of the LPU with the other
hand, pull the LPU out of the slot along slide rails, as shown in
.
6.
Put the removed LPU on the antistatic mat.
7.
Install a new LPU. For the installation procedures, see "
."
Содержание S12500-X
Страница 35: ...26 Figure 20 Grounding the switch through the RTN wire of the DC power module...
Страница 80: ...71 Figure 51 Replacing an LPU 1 1 Loosen the captive screw 2 Pull the ejector levers outward...
Страница 138: ...129 Figure 75 CXP fiber cable 1 Connector 2 Pull latch 1 2...