115
Figure 64
LSX1SUP10A1 LEDs
(1) Management Ethernet port LED (LINK)
(2) Management Ethernet port LED (ACT)
(3) Fan LED
(4) Power module status LED
(5) Card status LEDs
(6) MPU active/standby status LED
Management Ethernet port LEDs
The MPU has one LINK LED and one ACT LED to indicate the link status and data forwarding status of the
management Ethernet port.
Table 53
Management Ethernet port LED description
LINK ACT
Description
On Flashing
A link is present, and the management Ethernet port is receiving or
sending data.
On
Off
A link is present.
Off
Off
No link is present.
Fan LEDs
The MPU provides two LEDs (OK and FAIL) to indicate the status of the fan tray.
Table 54
Fan LED description
OK FAIL Description
On
Off
All fan trays are operating correctly.
Off
On
A fan tray problem is present or no fan tray is in position.
Off
Off
The switch is not powered on.
Power module status LEDs
The MPU provides two LEDs (OK and FAIL) to indicate the status of the power modules.
Table 55
Power module LED description
OK FAIL Description
On
Off
All power modules are operating correctly.
Off
On
A minimum of one power module is faulty.
Off
Off
The switch is not powered on.
Содержание S12500-X
Страница 35: ...26 Figure 20 Grounding the switch through the RTN wire of the DC power module...
Страница 80: ...71 Figure 51 Replacing an LPU 1 1 Loosen the captive screw 2 Pull the ejector levers outward...
Страница 138: ...129 Figure 75 CXP fiber cable 1 Connector 2 Pull latch 1 2...
Страница 152: ...143 Figure 91 Cable routing from the left side for an S12510 X AC S12510 X DC switch...