MG510R Calibration
3
W450256 Rev A 06/07
The MicroGuard
®
510 Display
Command Entry
The keys that are identified as
A
,
B
,
C
, and
D
will be used most for the procedures described in this
document and their function will vary depending on the routine being performed. Commands for each
routine will show in the information window as text adjacent to the keys. Follow directions for each
routine carefully.
Number Entry
The display does not have a numerical keypad so when numbers are required, the display will change
to enable number entry.
Keys
B
and
D
are used to scroll left and right. The “cursor” will appear as flashing < > brackets on
either side of the number. Key
A
is used to enter the number. Key
C
is used to exit the number entry
subroutine.
As each number is selected, press key
A
to enter it into the system. The number will then appear
in the [ ] brackets. Up to five numbers may be entered. When entering a negative value, enter the
numbers and decimal first, then enter the minus sign. If you enter a number incorrectly, select the
< backspace and press key
A
. When all digits look correct, press key
C
to calibrate the complete
number.
Example: To enter the value “-2.98”, do the following:
Press key
1.
B
or
D
until the number “2” is selected (indicated by flashing < > brackets) and then
press key
A
to enter the number
Select the decimal “.” then press key
2.
A
.
Repeat the previous steps to enter the number “9” and “8”.
3.
After the numbers are entered, press key
4.
B
or
D
until the minus sign “-” is selected and then
press key
A
.
If the value is correct, press key
5.
C
to exit.
TEST
SET
A
C
B
D
TEST
SET
A
C
B
D
Содержание MicroGuard 510 Retrofit
Страница 1: ...MicroGuard 510 Retrofit Rated Capacity Indicator System Calibration...
Страница 2: ......
Страница 40: ...MG510R Calibration 36 W450256 Rev A 06 07...
Страница 46: ...MG510R Calibration A 6 W450256 Rev A 06 07...
Страница 54: ...MG510R Calibration B 8 W450256 Rev A 06 07...
Страница 55: ......