MG510R Calibration
11
W450256 Rev A 06/07
Menu 01 – Crane Data
This menu displays the status of the personality.
TEST
SET
Press the key adjacent to either “Menu Up” or “Menu Down” until “01 Crane Data” appears in the
information window at the right.
Press the key adjacent to “01 Crane Data” to enter the routine.
TEST
SET
If the system has been reset and is functioning correctly the display will read “Personality is Good”. If
there is no crane data present, or if the system has become corrupt, the display will read “Personality
not in use”.
To reset the entire system, the crane data reset key must be pressed. This function will erase the
personality memory which stores crane specific information and dimensions. It will also copy any
known data from the system chip (ROM) applications file to the working personality memory for use
by the system.
To reset crane data, press the key adjacent to “Reset Crane Pers. Data?”
TEST
SET
Then, press the key adjacent to “Yes! Calibrate!”, or to exit without resetting, press the key adjacent
to “No, Exit/Abort”.
The system will prompt you to “Enter Cal Seq...”, this is the same key combination used to enter
calibration mode. The system will show that it is “Calibrating...”.
When it has finished, it will return to the main routine menu. The display will read “Personality is
good”, indicating a successful transfer of data.
TEST
SET
Содержание MicroGuard 510 Retrofit
Страница 1: ...MicroGuard 510 Retrofit Rated Capacity Indicator System Calibration...
Страница 2: ......
Страница 40: ...MG510R Calibration 36 W450256 Rev A 06 07...
Страница 46: ...MG510R Calibration A 6 W450256 Rev A 06 07...
Страница 54: ...MG510R Calibration B 8 W450256 Rev A 06 07...
Страница 55: ......