MG510R Calibration
33
W450256 Rev A 06/07
Menu 16 - Data Retrieval
This menu is used to view radius/Moment, attachment data, and pressure data.
IMPoRTaNT!
DaTa CaN BE EDITED WhIlE IN ThIs RoUTINE. UsE CaUTIoN WhEN vIEWING ThIs
INfoRMaTIoN so as NoT To EDIT aNy DaTa.
TEST
SET
Press the key adjacent to either “Menu Up” or “Menu Down” until “16 Data Retrieval” appears in the
information window at the right.
Press the key adjacent to “16 Data Retrieval” to enter the routine.
TEST
SET
The system will ask “Do you want to monitor pressure?”. Select the key adjacent to “Yes”.
TEST
SET
The information for the boom piston pressure is displayed. When finished, press the key adjacent to “Exit”.
The system will ask “Do you want to edit Radius/Moment Data?” Select the key adjacent to “Yes”.
TEST
SET
The system will display the current data. Press the key adjacent to “Edit”.
TEST
SET
You will be prompted to enter data that was previously recorded in Appendix A as follows: 1) Edit
Extension; 2) Edit Len_s1; 3) Edit Len_s2; 4) Edit WG; 5) Edit WT. Use the keys adjacent to the
numerical values at the bottom of the window to scroll left or right and highlight each number. Use
the key adjacent to the value name to enter the number. When complete, the menu will automatically
change to enter the next value. To skip to the next value, press the key adjacent to “Exit”.
TEST
SET
Содержание MicroGuard 510 Retrofit
Страница 1: ...MicroGuard 510 Retrofit Rated Capacity Indicator System Calibration...
Страница 2: ......
Страница 40: ...MG510R Calibration 36 W450256 Rev A 06 07...
Страница 46: ...MG510R Calibration A 6 W450256 Rev A 06 07...
Страница 54: ...MG510R Calibration B 8 W450256 Rev A 06 07...
Страница 55: ......