MG510R Calibration
27
W450256 Rev A 06/07
Set the boom to the fully extended and fully retracted high low angle positions. The system
3.
should display the correct configuration (i.e. fully extended at low angle; indicating it is
gathering data with a fully extended boom at a low angle). If the reading is incorrect, press the
key adjacent to the appropriate menu to correct the configuration.
TEST
SET
The information window will display “NOT Calibrated” or “Calibrated” for each setting.
4.
For each of the four positions, measure the radius and enter the measurement when
5.
prompted. The corrected radii will not be entered or shown until all steps of the routine are
complete. Then the radius must be checked and verified before moving on.
When finished, press the key adjacent to “Calibrate” to store the calibration.
6.