MG510R Calibration
29
W450256 Rev A 06/07
Menu 12 - stowed attachments
This menu is used to enter data for stowed attachments.
TEST
SET
Press the key adjacent to either “Menu Up” or “Menu Down” until “12 Stowed Attachments” appears
in the information window at the right.
Press the key adjacent to “12 Stowed Attachments” to enter the routine.
Press the key adjacent to “Edit”.
TEST
SET
When prompted, enter the measurements for jibs, weights of jibs, etc. Use the keys adjacent to the
numerical values at the bottom of the window to scroll left or right and highlight each number. Use
the key adjacent to the value name to enter the number. When complete, the menu will automatically
change to enter the next value. To skip to the next value, press the key adjacent to “Exit”.
Note: Numbers must be entered in feet and tenths.
Adjust the center of gravity of the jib for proper hook weight when unit is stowed. The required jib data
can be gathered as follows:
Fly Weight - Weigh it!! Use the weight gathered during the erected attachment calibration. Refer to
the Data Retrieval Menu #16.
TEST
SET
Stowed G - Balance Jib on hook to find the center point. Compute the distance from the boom pivot
pin to this point when the jib is stowed. See Figure.
TEST
SET
Note: Stowed deduction will be noted on the load chart or cab plate.
TEST
SET
Note: This information should be entered before performing a main boom radius/moment
calibration, if it is to be calibrated with an attachment stowed.
(NoT rECommENDED)
.
Содержание MicroGuard 510 Retrofit
Страница 1: ...MicroGuard 510 Retrofit Rated Capacity Indicator System Calibration...
Страница 2: ......
Страница 40: ...MG510R Calibration 36 W450256 Rev A 06 07...
Страница 46: ...MG510R Calibration A 6 W450256 Rev A 06 07...
Страница 54: ...MG510R Calibration B 8 W450256 Rev A 06 07...
Страница 55: ......