MG510R Calibration
22
W450256 Rev A 06/07
When you have finished, press the key adjacent to “Yes” to store the data.
TEST
SET
TIP
After saving this calibration point, the system will be showing the proper hook weight and
working with the corrected radius. You can boom up to 45° and recheck the radius (45°
is probably the worst case angle, so if the radius still checks good here you can move on
to the next point with confidence).
Continue until all boom length points have been entered. When finished, press the key adjacent to
“Exit”. After calibrating the radius moment, reenter the radius moment routine, and press the key
adjacent to “No” when prompted to start a new calibration. This will take you to an edit screen and will
enable you to view the data for each boom length calibrated. Writing these numbers down will save
time should the calibration data be lost for any reason (refer to Appendix A to record values).