MG510R Calibration
13
W450256 Rev A 06/07
Menu 02 - Dimensions
This menu is used to enter the physical dimensions of the crane that were previously recorded in
Appendix A.
TEST
SET
Press the key adjacent to either “Menu Up” or “Menu Down” until “02 Dimensions” appears in the
information window at the right.
Press the key adjacent to “02 Dimensions” to enter the routine.
Press the key adjacent to “Swing Offset X.X”.
TEST
SET
Enter the value for the swing offset. The only time this measurement will be positive, is if the boom
pivot pin is in front of the center of rotation. Use the keys adjacent to the numerical values at the
bottom of the window to scroll left or right and highlight each number. Use the key adjacent to “Swing
Offset” to enter the number. When complete, the menu will automatically change to enter the next
value. To skip to the next value, press the key adjacent to “Exit”.
Note: Numbers must be entered in feet and tenths (xx.xx). Make sure to enter a negative value where
appropriate.
TEST
SET
Continue entering the remaining values. After each value is entered, the menu will automatically
change to enter the next value. When all values have been entered, the main menu will be displayed.
When you are finished, press the key adjacent to “Exit” to continue, otherwise, press the key adjacent
to “Edit” to correct any of the values entered.
Содержание MicroGuard 510 Retrofit
Страница 1: ...MicroGuard 510 Retrofit Rated Capacity Indicator System Calibration...
Страница 2: ......
Страница 40: ...MG510R Calibration 36 W450256 Rev A 06 07...
Страница 46: ...MG510R Calibration A 6 W450256 Rev A 06 07...
Страница 54: ...MG510R Calibration B 8 W450256 Rev A 06 07...
Страница 55: ......