MG510R Calibration
9
W450256 Rev A 06/07
Entering Calibration Data
m
WaRNING
WhEN ThE sysTEM Is IN CalIBRaTIoN MoDE, aUToMaTIC ovERloaD CoNTRols aRE
DIsaBlED. ThE CRaNE oPERaToR Is REsPoNsIBlE foR PRoPER loaDING of ThE CRaNE
WhIlE PERfoRMING CalIBRaTIoN.
To enter calibration data it is necessary to put the system in calibration mode. Once in calibration
mode, you will have five (5) seconds to enter the security key sequence.
To access calibration mode:
Hold down the
1.
TEST
and
SET
keys simultaneously. The audible alarm will sound and you will
be prompted to enter the security key code.
Enter the security code in order (1, 2, 3, 4) as shown.
2.
TEST
SET
MicroGuard-510
Calibration entry security.
Enter correct key sequence.
1
4
3
2
The system is now in calibration mode and ready to receive calibration data. Use the keys adjacent to
the titles “Menu Up” and “Menu Down” to scroll through the following menus:
00 Error codes – Displays system information and error codes.
01 Crane Data – Used to reset and backup the crane personality data.
02 Dimensions – Used to enter the crane geometry dimensions previously recorded.
03 Extension Sensor – Used to set the zero point and span of the extension sensor.
04 Angle Sensor – Used to set the zero point and span point for the angle sensor.
05 Swing Potentiometer – Used to set the zero point and direction for the swing potentiometer.
06 Pressure – Used to calibrate the lift cylinder dimensions and load.
07 Radius/Moment – Used to calibrate the radius and moment for the main boom.
08 Boom Deflection – Used to calibrate deflection for the main boom and attachments.
09 Compensation – Sets rod side pressure compensation when booming down.
10 Erected Attachments – Used to calibrate the radii, moments, and dimensions of erected
attachments.
11 Auxiliary Head – Used to enter the dimensions of the auxiliary head.
12 Stowed Attachments – Used to enable or disable stowed attachments.
13 Digital Inputs – Used to view the status of digital inputs.
14 Enable Attachments – Used to enable or disable attachments in the system.
15 Enable Winches – Used to enable or disable winches in the system
16 Data Retrieval – Used to view radius moment, attachments, and pressure data as needed.
17 Language – Used to set the language for main display.
With the desired menu displayed, press the key adjacent to the menu name to select.
Содержание MicroGuard 510 Retrofit
Страница 1: ...MicroGuard 510 Retrofit Rated Capacity Indicator System Calibration...
Страница 2: ......
Страница 40: ...MG510R Calibration 36 W450256 Rev A 06 07...
Страница 46: ...MG510R Calibration A 6 W450256 Rev A 06 07...
Страница 54: ...MG510R Calibration B 8 W450256 Rev A 06 07...
Страница 55: ......