MG510R Calibration
12
W450256 Rev A 06/07
The system also contains a backup function that allows the installer/calibrator to retain a copy of the
personality information after the unit is calibrated. This system consists of the following components:
System Program Chip (ROM)
1.
Battery Backed RAM
2.
Personality Chip
3.
To back up the personality data, press the
key adjacent to “Backup Personality to RAM
Module”.
Then, press the key adjacent to “Yes!
Calibrate!”, or to exit without resetting, press
the key adjacent to “No, Exit/Abort”.
The system will prompt you to “Enter Cal
Seq...”, this is the same key combination used
to enter calibration mode. The system will
show that it is “Calibrating...”.
Pressing the button again after calibrating the backup will take you to the “Backup Personality from
Ram mode” where you select the option and calibrate the back up.
To copy the backup file to a blank personality chip:
Turn the system off and remove the existing personality chip.
1.
Install the blank personality chip.
2.
Turn the system on.
3.
Press the select button and enter the security code.
4.
The personality data will be copied from RAM to the new chip.
Note: The backup procedure is used at the end of all calibration steps or anytime a the current
personality is desirable. A copy of the personality data should be retained in case of computer failure.
System Program Chip
Battery Backed RAM
Personality Chip
IC16
IC17
IC18
Содержание MicroGuard 510 Retrofit
Страница 1: ...MicroGuard 510 Retrofit Rated Capacity Indicator System Calibration...
Страница 2: ......
Страница 40: ...MG510R Calibration 36 W450256 Rev A 06 07...
Страница 46: ...MG510R Calibration A 6 W450256 Rev A 06 07...
Страница 54: ...MG510R Calibration B 8 W450256 Rev A 06 07...