Appendix B - Data Exchanged
3A6338F
35
Blue Sensor Configuration Installed
Blue Sensor Configuration Installed is an integer that
defines the configuration of the sensor on the tank
stand. The following values correspond to the different
configurations available for the tank stand.
Recirculation Flow Rate
Recirculation Flow Rate is an integer used to define the
flow rate at which material will be recirculated.
Park Using Recirculation Valves Enabled
Park Using Recirculation Valves is a boolean that, when
enabled, will command the EFR to use the recirculation
valves instead of the dispense valves when parking the
pumps.
Park After Recirculation is Complete
Enabled
Park After Recirculation is Complete is a boolean that,
when enabled, will command the EFR to automatically
park the pump once recirculation is complete.
Recirculation Mode
Recirculation Mode is an integer that defines the mode
in which the recirculation will run. The following values
correspond to the different configurations available for
Recirculation Mode.
Disable Mode:
The EFR will disable all recirculation
features.
Manual Mode:
The EFR will recirculate by sending a 1
to Recirculation Request. The EFR will continue to
recirculate until the Recirculation Request is set to 0.
Timer Mode:
The EFR will recirculate for a specific
amount of time after a preset amount of time has
expired. To start the timer mode recirculation feature,
set the Recirculation Request to 1. When ready to
continue the dispense, set the Recirculation Request to
0, and trigger a dispense.
Recirculation Timer On Time
Recirculation Timer On Time is an integer that defines
the amount of time that the recirculation Timer Mode will
use to keep the system recirculating.
Recirculation Timer Off Time
Recirculation Timer Off Time is an integer that defines
the amount of time that the recirculation Timer Mode will
wait until it starts the Recirculation Time On Time.
Recirculation Timer Time Remaining
Recirculation Timer Time Remaining is an integer used
to define the amount of time remaining before the
recirculation toggles to on/off.
Value
Configuration
1
Low and High Sensor Installed
2
Low and Mid Sensor Installed
3
Mid and High Sensor Installed
4
Low, Mid, and High Sensor
Installed
Value
Park Using Recirculation
Valves
0
Not Enabled
1
Enabled
Value
Park After Recirculation is
Complete
0
Not Enabled
1
Enabled
Value
Recirculation Mode
0
Disable
1
Manual
2
Timer