Available Internal Data
10
3A6338F
* Refer to output bit “Step Time for Input Bytes 6 and 7
to Count Up Request.” If set, this data will increment
starting from 0 during an active dispense.
◆
If start and stop are time critical, do not use the EFR
EFR Gateway Run Sequence timing diagram shown
on page 16, or the EFR Gateway Run Sequence in
Operator Mode timing diagram shown on page 17.
Instead, use the EFR Gateway Run Sequence
Operator Sequence with Voltex timing diagram
shown on page 18, and the EFR Gateway Run
Sequence with Voltex timing diagram shown on page
19 to control the sequence on the PLC. This will
ensure that the motor is up to speed when
commanding the bead to start and stop.
8
Blue Pump Inlet Pressure (XXXX.X bar)
uint16
0-7
14
8-15
15
9
Pump Flow Rate (XXXX cc/min)
uint16
0-7
16
8-15
17
10
Active Error Number Requiring Acknowledgment
uint8
0-7
18
11
Active Operator Mode Dispense Flow Rate
(XXXX cc/min)
uint16
0-7
19
8-15
20
12
Data Exchanged Element Selected
uint8
0-7
21
13
Data Exchanged Element Value
uint16
0-7
22
8-15
23
14
Selected Step of the Active Sequence
uint8
0-7
24
15
Selected Step Amount (XXXX.XX)
uint32
0-7
25
8-15
26
16-23
27
24-31
28
16
Selected Step Shot Type
uint8
0-7
29
17
Selected Step Flow Rate (XXXX cc/min)
uint16
0-7
30
8-15
31
18
Selected Step Calibration (XX.XX)
uint16
0-7
32
8-15
33
19
Total Sequence Amount Requested (XXXX.XX cc)
uint32
0-7
34
8-15
35
16-23
36
24-31
37
20
Total Sequence Amount Dispensed (XXXX.XX cc)
uint32
0-7
38
8-15
39
16-23
40
24-31
41
Instance ID
Description
Data Type
BIT
Input Byte
Index’s