Available Internal Data
12
3A6338F
*
If set, control of the EFR from the ADM will be
disabled.
❖
If set, the “Time Remaining to Complete Step” data
from previous table will increase starting from 0.
◆
If set, all requests outlined in the table above will be
ignored by the EFR system, except “Acknowledging
of the Active Error Number” and “System Shutdown
Request.”
†
If set, the PLC must provide a valid “Heartbeat to
EFR” signal to the EFR to control the system. If a
valid signal is removed, the EFR system will shut
down.
‡
If the “PLC to EFR Heartbeat Request” bit is set, the
PLC must provide a dynamic signal (high, then low,
then high, then low, …), changing at a maximum
time of every 10 seconds.
13
{Reserved Word}
uint16
0-7
20
8-15
21
Instance ID
Description
Data Type
BIT
Output Byte
Index’s