Appendix B - Data Exchanged
30
3A6338F
ADM Pressure Units
ADM Pressure Units tells the EFR system what units the
pressure will be displayed in on the ADM. The following
values correspond to the various pressure units the EFR
ADM offers.
Pressure Imbalance Alarm Enabled
Pressure Imbalance Alarm Enabled is a boolean that
can enable or disable the ability to view pressure
imbalances between the red pump and the blue pump.
The following values correspond to the different states
the Pressure Imbalance Alarm boolean can be set to.
Pressure Imbalance Alarm Level
Pressure Imbalance Alarm Level is an integer used to
trigger the pressure imbalance alarm.
Red Pump Size
Red Pump Size is an integer used to define the size of
the red z pump.
Blue Pump Size
Blue Pump Size is an integer used to define the size of
the blue z pump.
Red Specific Gravity
Red Specific Gravity is an integer used to define the
specific gravity of the material in the red z pump.
Blue Specific Gravity
Blue Specific Gravity is an integer used to define the
specific gravity of the material in the blue z pump.
Gel Timer Enabled
Gel Timer Enabled is a boolean that can enable or
disable the Gel Timer feature. The following values
correspond to the different states the Gel Timer boolean
can be set to.
Gel Timer Idle Period
Gel Timer Idle Period is an integer used to define the
idle state of the gel timer before the gel timer causes a
dispense.
Gel Timer Alarm
Gel Timer Alarm is an integer used to define the alarm
state of the gel timer.
Gel Timer Repeat Unit
Gel Timer Repeat Unit is an integer used to define the
amount of material dispensed for the gel timer shot.
Gel Timer Sequence Selected
Gel Timer Sequence Selected is an integer used to
define the sequence that will run when the gel timer
expires.
NOTE:
To use the active sequence as the selected
sequence for the gel timer, a new value of zero must be
sent across the data exchange. If a new value of zero is
not sent, the number sent across the data exchange will
correspond to the sequence selected for the gel timer.
Smart Prime Repeat Unit
Smart Prime Repeat Unit is an integer used to define
the amount of material dispensed for the smart prime.
Smart Prime Sequence Selected
Smart Prime Sequence Selected is an integer used to
define the sequence that will run when smart prime is
enabled.
NOTE:
To use the active sequence as the selected
sequence for smart prime, a new value of zero must be
sent across the data exchange. If a new value of zero is
not sent, the number sent across the data exchange will
correspond to the sequence selected for the gel timer.
Value
Pressure Units State
0
PSI
1
Bar
Value
Pressure Imbalance
Alarm State
0
Not Enabled
1
Enabled
Value
Gel Timer Enabled State
0
Not Enabled
1
Enabled