Appendix C - Sequence Step Data Exchange
36
3A6338F
Appendix C - Sequence Step Data Exchange
The Sequence Data Exchange is a condensed structure used to read and edit a number of steps in a sequence
across a set of bytes. If multiple steps of sequences are needed, they must be cycled through.
Below is a timing diagram showing the Sequence Step Data Exchange portion of EFR CGM Map.
NOTE:
A 50ms delay is suggested between each CGM signal.
When utilizing the Sequence Step Data Exchange, the first element that must be passed to the EFR is the Desired
Step of the Active Sequence. Once the EFR receives that element, the EFR will update the Sequence Step Data
Exchange Automation Inputs Elements for the desired step. After the Sequence Step Data Exchange Automation
Inputs Elements have been updated, the Selected Step of the Active Sequence can be used to confirm the desired
step data has populated the Sequence Step Data Exchange Automation Inputs Elements. Once the data has been
confirmed for the desired step, the Sequence Step Data Exchange Automation Outputs Elements can be used to
request new values to the EFR. If the values supplied are within the operable range of the elements, the EFR will
accept the values and reflect the new values to the corresponding elements of the Sequence Step Data Exchange
Automation Inputs Elements.
Automation Inputs (EFR Outputs)
Selected Step of the Active Sequence
Selected Step Amount
Selected Step Shot Type
Selected Step Flow Rate
Selected Step Calibration
Automation Outputs (EFR Inputs)
Desired Step of the Active Sequence
Desired Step Amount
Desired Step Shot Type
Desired Step Flow Rate
Desired Step Calibration
PLC State
Reading Sequence
Editing Sequence
Key
Duration that PLC can Read the information
Duration that PLC can Edit the information
EFR Gateway Editing Sequences
Changing
Steps