Automation Inputs (signals from EFR system to PLC)
Instance ID
Description
Data Type
BIT
Input Byte
Index’s
1
Heartbeat To PLC
Boolean
0
0
System On
Boolean
1
System Ready
Boolean
2
Alarms Present
Boolean
3
Deviations Present
Boolean
4
Advisories Present
Boolean
5
Current Sequence is Playing
Boolean
6
Current Sequence is Paused
Boolean
7
Current Sequence is Stopped
Boolean
8
1
Dispense Valve Open
Boolean
9
System is Priming
Boolean
10
System is Purging
Boolean
11
System is Parking
Boolean
12
System is Depressurizing
Boolean
13
Gel Shot is Running
Boolean
14
EFR is Dispensing
Boolean
15
ADM Lockout is Active
Boolean
16
2
Incrementing Step Time is Active
Boolean
17
PLC Monitor Only is Active
Boolean
18
PLC to EFR Heartbeat is Enabled and Required to
Control
Boolean
19
Voltex Dynamic Mix Valve, Motor Running
Boolean
20
EFR Dispense Wait Completed for Dispensing *
◆
Boolean
21
Voltex Dynamic Mix Valve, Motor is at Target Speed
Boolean
22
Voltex Dynamic Mix Valve, Air Injection Valve Opened
Boolean
23
Red Tank is Filling
Boolean
24
3
Red Tank Fill Level Bit 1
Boolean
25
Red Tank Fill Level Bit 2
Boolean
26
Blue Tank is Filling
Boolean
27
Blue Tank Fill Level Bit 1
Boolean
28
Blue Tank Fill Level Bit 2
Boolean
29
System is Recirculating
Boolean
30
{Reserved Bits}
Boolean
31
2
Current Active Sequence
uint8
0-7
4
3
Current Step of the Active Sequence
uint8
0-7
5
4
Time Remaining to Complete Step (*or time completed
starting from 0) (XX.X s)
uint16
0-7
6
8-15
7
5
Red Pump Outlet Pressure (XXXX.X bar)
uint16
0-7
8
8-15
9
6
Blue Pump Outlet Pressure (XXXX.X bar)
uint16
0-7
10
8-15
11
7
Red Pump Inlet Pressure (XXXX.X bar)
uint16
0-7
12
8-15
13