Available Internal Data
3A6338F
11
Automation Outputs (signals from PLC to EFR system)
Instance ID
Description
Data Type
BIT
Output Byte
Index’s
1
System Enable Request
Boolean
0
0
System Shutdown Request
Boolean
1
Start Current Sequence/Step, Trigger Operator
Mode
Boolean
2
Pause Current Sequence
Boolean
3
Stop Current Sequence
Boolean
4
Priming Request
Boolean
5
Purge Request
Boolean
6
Parking Request
Boolean
7
Depressurizing Request
Boolean
8
1
*ADM Lockout Request
Boolean
9
❖
Increment Step Time for Input Bytes 6 and 7
Request
Boolean
10
◆
PLC Monitor Only Request
Boolean
11
† PLC to EFR Heartbeat Enable Request
Boolean
12
‡ Heartbeat to EFR
Boolean
13
Voltex Dynamic Mix Valve, Motor On Request
Boolean
14
Voltex Dynamic Mix Valve, Air Injection Open
Request
Boolean
15
Red Tank Auto/Manual Fill Request
Boolean
16
2
Blue Tank Auto/Manual Fill Request
Boolean
17
Recirculation Request
Boolean
18
{Reserved Bits}
Boolean
19
{Reserved Bits}
Boolean
20
{Reserved Bits}
Boolean
21
{Reserved Bits}
Boolean
22
{Reserved Bits}
Boolean
23
3
Desired Active Sequence
uint8
0-7
3
4
Acknowledging of the Active Error Number
uint8
0-7
4
5
Desired Operator Mode Dispense Flow Rate (XXXX
cc/min)
uint16
0-7
5
8-15
6
6
Data Exchanged Element Desired
uint8
0-7
7
7
Data Exchanged Element Desired Value
uint16
0-7
8
8-15
9
8
Desired Step of the Active Sequence
uint8
0-7
10
9
Desired Step Amount (XXXX.XX)
uint32
0-7
11
8-15
12
16-23
13
24-31
14
10
Desired Step Shot Type
uint8
0-7
15
11
Desired Step Flow Rate (XXXX cc/min)
uint16
0-7
16
8-15
17
12
Desired Step Calibration (XX.XX)
uint16
0-7
18
8-15
19