Appendix B - Data Exchanged
3A6338F
33
Sequence Start Outlet Pressure for Red
Pump
Sequence Start Outlet Pressure for Red Pump is an
integer that represents the outlet pressure of the red
pump once the active sequence begins dispensing.
NOTE:
This integer will only be populated after the
active sequence is done dispensing.
NOTE:
This integer can only be read by the PLC.
Sequence Start Outlet Pressure for Blue
Pump
Sequence Start Outlet Pressure for Blue Pump is an
integer that represents the outlet pressure of the blue
pump once the active sequence begins dispensing.
NOTE:
This integer will only be populated after the
active sequence is done dispensing.
NOTE:
This integer can only be read by the PLC.
Sequence End Outlet Pressure for Red
Pump
Sequence End Outlet Pressure for Red Pump is an
integer that represents the outlet pressure of the red
pump once the active sequence is done dispensing.
NOTE:
This integer will only be populated after the
active sequence is done dispensing.
NOTE:
This integer can only be read by the PLC.
Sequence End Outlet Pressure for Blue
Pump
Sequence End Outlet Pressure for Blue Pump is an
integer that represents the outlet pressure of the blue
pump once the active sequence is done dispensing.
NOTE:
This integer will only be populated after the
active sequence is done dispensing.
NOTE:
This integer can only be read by the PLC.
Sequence Inlet Pressure for Red Pump
Sequence Inlet Pressure for Red Pump is an integer
that represents the inlet pressure of the red pump for the
current sequence being dispensed.
NOTE:
This integer will only be populated after the
active sequence is done dispensing.
NOTE:
This integer can only be read by the PLC.
Sequence Inlet Pressure for Blue Pump
Sequence Inlet Pressure for Blue Pump is an integer
that represents the inlet pressure of the blue pump for
the current sequence being dispensed.
NOTE:
This integer will only be populated after the
active sequence is done dispensing.
NOTE:
This integer can only be read by the PLC.
Voltex Dynamic Mix Valve, Motor Target
Speed
Motor Target Speed is an integer used to define the
speed of the Voltex Dynamic Mix Valve mixer. The
speed ranges between 0 rpm and 4400 rpm.
Voltex Dynamic Mix Valve, Motor Ramp Up
Time
Motor Ramp Up Time is an integer used to define the
period of time in which the motor will reach the Motor
Target Speed.
Voltex Dynamic Mix Valve, EFR Dispense
Wait Enable
EFR Dispense Wait Enable is a boolean used to make
the EFR wait until the Voltex Dynamic Mix Valve motor
speed has reached the target speed before dispensing.
If not enabled, the EFR will begin to dispense as soon
as the dispensing signal is received.
Value
EFR Dispense Wait
0
Disabled
1
Enabled