Appendix B - Data Exchanged
34
3A6338F
Voltex Dynamic Mix Valve, Air Nucleation
Enable
Air Nucleation Enable is a boolean that allows the air
nucleation to run when a dispensing signal is received
by the Voltex Dynamic Mix Valve.
Voltex Dynamic Mix Valve, Air Nucleation
Delay Time
Air Nucleation Delay Time is an integer used to delay
the start of air nucleation after a dispensed signal is
received. This time must expired before the air
nucleation can toggle between the on and off timers.
Voltex Dynamic Mix Valve, Air Nucleation
On Time
Air Nucleation On Time is an integer used to define the
amount of time that the air nucleation will stay on before
toggling off.
Voltex Dynamic Mix Valve, Air Nucleation
Off Time
Air Nucleation Off Time is an integer used to define the
amount of time that the air nucleation will stay off before
toggling on.
Voltex Dynamic Mix Valve, Actual Motor
Speed
Actual Motor Speed is an integer that represents the
actual speed that the motor is currently running at.
Voltex Dynamic Mix Valve, Red Valve
Pressure
Red Valve Pressure is an integer that represents the
actual pressure of the red material in the valve.
Voltex Dynamic Mix Valve, Blue Valve
Pressure
Blue Valve Pressure is an integer that represents the
actual pressure of the blue material in the valve.
Red Refill Setting
Red Refill Setting is an integer that defines the mode the
tank stand is in. The following values correspond to the
different modes available for the tank stand.
Red Refill Timeout
Red Refill Timeout is an integer that defines the amount
of time the tank stands will fill before the auto refill
timeout deviation will occur and stop the refill process if
the full level is not reached.
Red Sensor Configuration Installed
Red Sensor Configuration Installed is an integer that
defines the configuration of the sensor on the tank
stand. The following values correspond to the different
configurations available for the tank stand.
Blue Refill Setting
Blue Refill Setting is an integer that defines the mode
the tank stand is in. The following values correspond to
the different modes available for the tank stand.
Blue Refill Timeout
Blue Refill Timeout is an integer that defines the amount
of time the tank stands will fill before the auto refill
timeout deviation will occur and stop the refill process if
the full level is not reached.
Value
Air Nucleation
0
Disabled
1
Enabled
Value
Refill Setting
0
Disable
1
Monitor Only
2
Manual Fill
3
Auto Top-Off
Value
Configuration
1
Low and High Sensor Installed
2
Low and Mid Sensor Installed
3
Mid and High Sensor Installed
4
Low, Mid, and High Sensor
Installed
Value
Refill Setting
0
Disable
1
Monitor Only
2
Manual Fill
3
Auto Top-Off