Available Internal Data
3A6338F
21
An ON pulse across the System Shutdown Request bit will stop the sequence and turn the System On bit OFF,
making the system inactive.
A toggle OFF followed by a toggle ON of the System Enabled Request bit will put the system back into the active
state after the EFR has shut down.
The Sequence Data must be read before the EFR
finishes running another sequence. If the Sequence
Data is not read before finishing the sequence, the data
will be overwritten with new Sequence Data.
The Sequence Data consists of:
•
Total Sequence Amount Requested
•
Total Sequence Amount Dispensed
•
Sequence Start Outlet Pressure for Red Pump
•
Sequence Start Outlet Pressure for Blue Pump
•
Sequence End Outlet Pressure for Red Pump
•
Sequence End Outlet Pressure for Blue Pump
•
Sequence Inlet Pressure for Red Pump
•
Sequence Inlet Pressure for Blue Pump
Automation Inputs (EFR Outputs)
System On
System Ready
Alarms Present
Deviations Present
Advisories Present
Dispensed Valve Open
Automation Outputs (EFR Inputs)
System Enable Request
Start Current Sequence/Step, Trigger Operator Mode
System Shutdown Request
EFR State
Sequence Running
Key
EFR Sequence is running
EFR Gateway Emergency Shutdown
Automation Inputs (EFR Outputs)
System Ready
System is Playing
System is Paused
System is Stopped
PLC State
Reading Sequence Data
Key
Duration that PLC can Read the Sequence Information
EFR Gateway Sequence Data