motor then ramps to 100% of the required airflow. A one (1)
minute OFF delay at 100% of the cooling airflow is provided.
50% CFM
1/2 min
100% CFM
100% CFM
1 min
OFF
OFF
•
Profile C
Profile C
Profile C
Profile C
Profile C ramps up to 85% of the full cooling demand airflow
and operates there for approximately 7 1/2 minutes. The
motor then steps up to the full demand airflow. Profile C
also has a one (1) minute 100% OFF delay.
100% CFM
OFF
OFF
1
2
A
OFF
OFF
B
ON
OFF
C
OFF
ON
D*
ON
ON
Switch Bank: S3
Cooling
Airflow
DIP Switch No.
(*Indicates factory setting)
3
4
Normal*
OFF
OFF
10%
ON
OFF
-10%
OFF
ON
Normal
ON
ON
DIP Switch No.
(*Indic ates factory setting)
Switch Bank: S3
Adjust Taps
•
Profile D
Profile D
Profile D
Profile D
Profile D ramps up to 50% of the demand for 1/2 minute,
then ramps to 85% of the full cooling demand airflow and
operates there for approximately 7 1/2 minutes. The motor
then steps up to the full demand airflow. Profile D has a 1/2
minute at 50% airflow OFF delay.
OFF
OFF
*DVC81155CX*
*DVC80905CX*
*DVC80703BX*
*MVC81155CX*
*MVC80905CX*
*MVC80704BX*
To set airflow:
C ------- 7.5 min/82% 60 sec/100%
A ------- -------- 60 sec/100%
TAP 1 2 3 4 5 6 7 8
To set Comfort Mode:
B ON OFF ON OFF ON OFF ON OFF
C OFF ON OFF ON OFF ON OFF ON
B ------- 30 sec/50% 60 sec/100%
D ON ON ON ON ON ON ON ON
D 30 sec/50% 7.5 min/82% 30 sec/50%
Select desired Comfort Mode profile
(see profiles above). Set switches 5 and 6 to the appropriate
ON / OFF positions.
A OFF OFF OFF OFF OFF OFF OFF OFF
Model Tap Low Stage High Stage Low Stage High Stage
Cool Cool Heat Heat
Cool Adjust Profile Heat
Selection Selection Selection Selection
Switches Switches Switches Switches
Profiles Pre-Run Short-Run OFF Delay
(1) Select model and desired
high stage cooling airflow. Determine the corresponding tap
( A, B, C, or D ). Set dip switches 1 and 2 to the appropriate
ON / OFF positions. (2) Select model and desired high stage
heating airflow. Determine the corresponding tap ( A, B, C, or
D ). Set dip switches 7 and 8 to the appropriate ON / OFF
positions. (3) Select the airflow adjustment factor taps A and
D are 1; Tap B is +10%; Tap C -10%. Set dip switches 3 and 4
to the appropriate ON / OFF positions.
Speed Selection Dip Switches
390
520
650
780
A
B
C
D
600
800
1000
1200
735
805
875
935
1050
1150
1250
1350
520
715
910
1170
A
B
C
D
800
1100
1400
1800
945
1015
1085
1155
1350
1450
1550
1650
553
748
943
1203
A
B
C
D
850
1150
1450
1850
1085
1155
1225
1260
1550
1650
1750
1800
390
520
715
910
A
B
C
D
600
800
1100
1400
875
945
1015
1085
1250
1350
1450
1550
520
715
910
1170
A
B
C
D
800
1100
1400
1800
1050
1120
1190
1260
1500
1600
1700
1800
520
715
910
1175
A
B
C
D
800
1100
1400
1800
1210
1225
1245
1260
1725
1750
1775
1800