Adhere to the following warnings and cautions when installing, adjusting, altering, servicing, or operating the furnace.   To ensure proper
installation and operation, thoroughly read this manual for specifics pertaining to the installation and application of this product.

T

O

 

PREVENT

 

PERSONAL

 

INJURY

 

OR

 

DEATH

 

DUE

 

TO

 

IMPROPER

 

INSTALLATION

,

 

ADJUSTMENT

,

 

ALTERATION

,

 

SERVICE

 

OR

 

MAINTENANCE

,

 

REFER

 

TO

 

THIS

 

MANUAL

.

 

F

OR

 

ADDITIONAL

 

ASSISTANCE

 

OR

 

INFORMATION

,

 

CONSULT

 

A

 

QUALIFIED

 

INSTALLER

,

 

SERVICER

 

AGENCY

 

OR

 

THE

 

GAS

 

SUPPLIER

.

WARNING

I

F

 

THE

 

INFORMATION

 

IN

 

THESE

 

INSTRUCTIONS

 

IS

 

NOT

 

FOLLOWED

 

EXACTLY

,

 

A

 

FIRE

 

OR

 

EXPLOSION

 

MAY

 

RESULT

 

CAUSING

 

PROPERTY

DAMAGE

,

 

PERSONAL

 

INJURY

 

OR

 

LOSS

 

OF

 

LIFE

.

D

O

 

NOT

 

STORE

 

OR

 

USE

 

GASOLINE

 

OR

 

OTHER

 

FLAMMABLE

 

VAPORS

 

AND

 

LIQUIDS

 

IN

 

THE

 

VICINITY

 

OF

 

THIS

 

OR

 

ANY

 

OTHER

 

APPLIANCE

.

D

O

 

NOT

 

TRY

 

TO

 

LIGHT

 

ANY

 

APPLIANCE

.

D

O

 

NOT

 

TOUCH

 

ANY

 

ELECTRICAL

 

SWITCH

;

 

DO

 

NOT

 

USE

 

ANY

 

PHONE

 

IN

 

YOUR

 

BUILDING

.

I

MMEDIATELY

 

CALL

 

YOUR

 

GAS

 

SUPPLIER

 

FROM

 

A

 

NEIGHBOR

S

 

PHONE

.

 

F

OLLOW

 

THE

 

GAS

 

SUPPLIER

S

 

INSTRUCTIONS

.

I

F

 

YOU

 

CANNOT

 

REACH

 

YOUR

 

GAS

 

SUPPLIER

,

 

CALL

 

THE

 

FIRE

 

DEPARTMENT

.

I

NSTALLATION

 

AND

 

SERVICE

 

MUST

 

BE

 

PERFORMED

 

BY

 

A

 

QUALIFIED

 

INSTALLER

,

 

SERVICE

 

AGENCY

 

OR

 

THE

 

GAS

 

SUPPLIER

.

WHAT

 

TO

 

DO

 

IF

 

YOU

 

SMELL

 

GAS:

WARNING

T

HIS

 

PRODUCT

 

CONTAINS

 

OR

 

PRODUCES

 

A

 

CHEMICAL

 

OR

 

CHEMICALS

 

WHICH

 

MAY

 

CAUSE

 

SERIOUS

 

ILLNESS

 

OR

 

DEATH

 

AND

 

WHICH

 

ARE

 

KNOWN

 

TO

 

THE

 

S

TATE

 

OF

 

C

ALIFORNIA

 

TO

 

CAUSE

 

CANCER

,

 

BIRTH

 

DEFECTS

 

OR

 

OTHER

 

REPRODUCTIVE

 

HARM

.

WARNING

H

EATING

 

UNIT

 

SHOULD

 

NOT

 

BE

 

UTILIZED

 

WITHOUT

 

REASONABLE

,

 

ROUTINE

,

 

INSPECTION

,

 

MAINTENANCE

 

AND

 

SUPERVISION

.

 

I

F

 

THE

 

BUILDING

 

IN

 

WHICH

 

ANY

 

SUCH

 

DEVICE

 

IS

 

LOCATED

 

WILL

 

BE

 

VACANT

,

 

CARE

 

SHOULD

 

BE

 

TAKEN

 

THAT

 

SUCH

 

DEVICE

 

IS

 

ROUTINELY

 

INSPECTED

,

 

MAINTAINED

 

AND

 

MONITORED

.

 

IN

 

THE

 

EVENT

 

THAT

 

THE

 

BUILDING

 

MAYBE

 

EXPOSED

 

TO

 

FREEZING

 

TEMPERATURES

 

AND

 

WILL

 

BE

 

VACANT

,

 

ALL

 

WATER

BEARING

 

PIPES

 

SHOULD

 

BE

 

DRAINED

,

 

THE

 

BUILDING

 

SHOULD

 

BE

 

PROPERLY

 

WINTERIZED

,

 

AND

 

THE

 

WATER

 

SOURCE

 

CLOSED

.

 

IN

 

THE

 

EVENT

 

THAT

 

THE

 

BUILDING

 

MAY

 

BE

 

EXPOSED

 

TO

 

FREEZING

 

TEMPERATURES

 

AND

 

WILL

 

BE

 

VACANT

,

 

ANY

 

HYDRONIC

 

COIL

 

UNITS

 

SHOULD

 

BE

 

DRAINED

 

AS

 

WELL

 

AND

,

 

IN

 

SUCH

 

CASE

,

 

ALTERNATIVE

 

HEAT

 

SOURCES

 

SHOULD

 

BE

 

UTILIZED

.

WARNING

T

O

 

PREVENT

 

POSSIBLE

 

PROPERTY

 

DAMAGE

,

 

PERSONAL

 

INJURY

 

OR

 

DEATH

 

DUE

 

TO

 

ELECTRICAL

 

SHOCK

,

 

THE

 

FURNACE

 

MUST

 

BE

 

LOCATED

 

TO

 

PROTECT

 

THE

 

ELECTRICAL

 

COMPONENTS

 

FROM

 

WATER

.

WARNING

 

 
 
 
 
 
 
 
 

 

 

 

CARBON MONOXIDE POISONING HAZARD  

-

 

 

Special Warning for Installation of Furnace or Air Handling Units in
Enclosed Areas such as Garages, Utility Rooms or Parking Areas

Carbon monoxide producing devices (such as an automobile, space
heater, gas water heater, etc.) should not be operated in enclosed areas
such as unventilated garages, utility rooms or parking areas because of
the danger of carbon monoxide (CO) poisoning resulting from the exhaust
emissions.  If a furnace or air handler is installed in an enclosed area such
as a garage, utility room or parking area and a carbon monoxide producing
device is operated therein, there must be adequate, direct outside
ventilation.

This ventilation is necessary to avoid the danger of CO poisoning which
can occur if a carbon monoxide producing device continues to operate in
the enclosed area.  Carbon monoxide emissions can be (re)circulated
throughout the structure if the furnace or air handler is operating in any
mode.

CO can cause serious illness including permanent brain damage or death.

B10259-216

S

HOULD

 

OVERHEATING

 

OCCUR

 

OR

 

THE

 

GAS

 

SUPPLY

 

FAIL

 

TO

 

SHUT

 

OFF

,

 

TURN

 

OFF

 

THE

 

MANUAL

 

GAS

 

SHUTOFF

 

VALVE

 

EXTERNAL

 

TO

 

THE

 

FURNACE

 

BEFORE

 

TURNING

 

OFF

 

THE

 

ELECTRICAL

 

SUPPLY

.

WARNING

P

OSSIBLE

 

PROPERTY

 

DAMAGE

,

 

PERSONAL

 

INJURY

 

OR

 

DEATH

 

DUE

 

TO

 

FIRE

,

 

EXPLOSION

,

 

SMOKE

,

 

SOOT

,

 

CONDENSATION

,

 

ELECTRICAL

 

SHOCK

 

OR

 

CARBON

 

MONOXIDE

 

MAY

 

RESULT

 

FROM

 

IMPROPER

 

INSTALLATION

,

 

REPAIR

 

OPERATION

,

 

OR

 

MAINTENANCE

 

OF

 

THIS

 

PRODUCT

.

WARNING

T

O

 

PREVENT

 

PERSONAL

 

INJURY

 

OR

 

DEATH

 

DUE

 

TO

 

IMPROPER

 

INSTALLATION

,

 

ADJUSTMENT

,

 

ALTERATION

,

 

SERVICE

 

OR

 

MAINTENANCE

,

 

REFER

 

TO

 

THIS

 

MANUAL

.

 

F

OR

 

ADDITIONAL

 

ASSISTANCE

 

OR

 

INFORMATION

,

 

CONSULT

 

A

 

QUALIFIED

 

INSTALLER

,

 

SERVICER

 

AGENCY

 

OR

 

THE

 

GAS

 

SUPPLIER

.

WARNING

T

HIS

 

UNIT

 

MUST

 

NOT

 

BE

 

USED

 

AS

 

A

 

CONSTRUCTION

 

HEATER

 

DURING

 

THE

 

FINISHING

 

PHASES

 

OF

 

CONSTRUCTION

 

ON

 

A

 

NEW

 

STRUCTURE

.

 

T

HIS

 

TYPE

 

OF

 

USE

 

MAY

 

RESULT

 

IN

 

PREMATURE

 

FAILURE

 

OF

 

THE

 

UNIT

 

DUE

 

TO

 

EXTREMELY

 

LOW

 

RETURN

 

AIR

 

TEMPERATURES

 

AND

 

EXPOSURE

 

TO

 

CORROSIVE

 

OR

 

VERY

 

DIRTY

 

ATMOSPHERES

.

WARNING

Содержание GDVC80703B

Страница 1: ...afety practices follow them The precautions listed in this Installation Manual are intended as supplemental to existing practices However if there is a direct conflict between existing practices and t...

Страница 2: ...L 12 CHECK 3 CHIMNEY CROWN CONDITION 12 CHECK 4 DEBRIS IN CLEANOUT 12 CHECK 5 LINER CONDITION 12 CHECK 6 DILUTION AIR 13 CHECK 7 COMPLETE THE INSTALLATION 13 FIX 1 LINER TERMINATION 13 FIX 2 CHANGE VE...

Страница 3: ...33 POWER UP 33 HEATING MODE 33 COOLING MODE 33 FAN ONLY MODE 34 OPERATIONAL CHECKS 34 SAFETY CIRCUIT DESCRIPTION 34 INTEGRATED CONTROL MODULE 34 PRIMARY LIMIT 34 AUXILIARY LIMIT 34 ROLLOUT LIMIT 34 P...

Страница 4: ...ANY HYDRONIC COIL UNITS SHOULD BE DRAINED AS WELL AND IN SUCH CASE ALTERNATIVE HEAT SOURCES SHOULD BE UTILIZED WARNING TO PREVENT POSSIBLE PROPERTY DAMAGE PERSONAL INJURY OR DEATH DUE TO ELECTRICAL S...

Страница 5: ...ntial these steps will help avoid exposing the inte gratedcontrolmoduletoelectrostaticdischarge Thisprocedureis applicable to both installed and non installed ungrounded fur naces 1 Disconnect all pow...

Страница 6: ...local plumbing or waste water codes and other applicable codes A copy of the National Fuel Gas Code NFPA 54 ANSI Z223 1 can be obtained from any of the following American National Standards Institute...

Страница 7: ...RE NOT APPROVED FOR HORIZON ARE NOT APPROVED FOR HORIZON ARE NOT APPROVED FOR HORIZON ARE NOT APPROVED FOR HORIZON T T T T TAL OR UPFL AL OR UPFL AL OR UPFL AL OR UPFL AL OR UPFLOW INST OW INST OW INS...

Страница 8: ...23 1 tion 1 23 1 tion 1 23 1 The following steps shall be fol lowedwitheachapplianceconnectedtotheventingsystemplaced inoperation whileanyotherappliancesconnectedtotheventing systemarenotinoperation a...

Страница 9: ...TION TION A A A A AIR IR IR IR IR R R R R REQUIREMENT EQUIREMENT EQUIREMENT EQUIREMENT EQUIREMENTS S S S S TO AVOID PROPERTY DAMAGE PERSONAL INJURY OR DEATH SUFFICIENT FRESH AIR FOR PROPER COMBUSTION...

Страница 10: ...Disconnecttheinduceddraftblowerpowerleads fluepipe andpressureswitchtubing 3 Removetheroundcutoutfromtherightsideofthewrapper 4 Remove and save the four screws that fasten the induced draft blower to...

Страница 11: ...C C CHECKLIST HECKLIST HECKLIST HECKLIST HECKLIST S S S S SUMMARY UMMARY UMMARY UMMARY UMMARY This checklist serves as a summary of the items to be checked beforeventingan80 furnaceintoamasonrychimne...

Страница 12: ...ey Fix 4 C C C C CHECK HECK HECK HECK HECK 5 L 5 L 5 L 5 L 5 LINER INER INER INER INER C C C C CONDITION ONDITION ONDITION ONDITION ONDITION Ifametallinerispresent itmustbechecked Itcannotbeassumed th...

Страница 13: ...t in accordance with nationally recognized building codes or stan dards OnesuchstandardwhichmaybereferencedistheStandard forChimneys Fireplaces Vents andSolidFuelBurningAppliances ANSI NFPA 211 Next u...

Страница 14: ...orts such as fire stops or thimbles must be used to prevent the B vent fromcomingintodirectcontactwiththetilelinerorchimneywalls Direct contact would result in higher heat loss with an increased possi...

Страница 15: ...ES MAY BE SHARP USE GLOVES AS A PRECAUTION WHEN REMOVING HOLE PLUGS WARNING Line voltage connections can be made through either the right or left side panel The furnace is shipped configured for a rig...

Страница 16: ...and dehumidification features require a jumper betweenY1 and O andY1 and DEHUM respectively NOTE NOTE NOTE NOTE NOTE Thermostat R requiredifoutdoorunitisequippedwitha Comfort Alert module or if the o...

Страница 17: ...binationcallforcooling T Stat anddehumidification DEHUM Stat 9 10 DEHUM Unused Move to the ON position to enable dehumidification ON OFF S5 F F F F FOSSIL OSSIL OSSIL OSSIL OSSIL F F F F FUEL UEL UEL...

Страница 18: ...e furnace can result in premature heat exchanger failure Gas pressures in excess of 13 inches water column can also cause permanent damage to the gas valve At all altitudes the manifold pressure must...

Страница 19: ...three inches long Installa1 8 NPTpipeplugfitting accessiblefortestgage connection immediately upstream of the gas supply connection to the furnace Use two pipe wrenches when making connection to the...

Страница 20: ...PANE G G G G GAS AS AS AS AS T T T T TANKS ANKS ANKS ANKS ANKS AND AND AND AND AND P P P P PIPING IPING IPING IPING IPING IF THE GAS FURNACE IS INSTALLED IN A BASEMENT AN EXCAVATED AREA OR CONFINED SP...

Страница 21: ...stalledbetweentheunitandtheutility roomwall Aroom closet oralcovemustnotbeusedasareturnair chamber When the furnace is used in connection with a cooling unit the furnaceshouldbeinstalledinparallelwith...

Страница 22: ...perly connected andgrounded Properpolaritymustbemaintainedforcorrectop eration Inadditiontothefollowingstart upandadjustmentitems refertofurtherinformationinOperationalCheckssection H H H H HEAT EAT E...

Страница 23: ...cessary adjust ments to pressure regulator gas piping size etc and or consult withlocalgasutility 5 Turn OFF gas to furnace at the manual shutoff valve and disconnect manometer Reinstall plug before t...

Страница 24: ...tion of the smallest gas meter dial 3 Calculate the number of seconds per cubic foot sec ft3 of gas being delivered to the furnace If the dial is a one cubic foot dial divide the number of seconds rec...

Страница 25: ...The cooling system manufacturer s instructions must be checked for required air flow Any electronic air cleaners or other devices may require specific air flows consult installation instructions of t...

Страница 26: ...Mode B ON OFF ON OFF ON OFF ON OFF C OFF ON OFF ON OFF ON OFF ON B 30 sec 50 60 sec 100 D ON ON ON ON ON ON ON ON D 30 sec 50 7 5 min 82 30 sec 50 Select desired Comfort Mode profile see profiles abo...

Страница 27: ...ctory setting 8 Select the desired heating speed tap by positioning switches7and8appropriately Refertofigureabove Verify CFMbynotingthenumberdisplayedonthedual7 segment LEDdisplay In general lower hea...

Страница 28: ...ystem controls are power with 24 VAC Thus a maximum of 4 wires between the equipment and thermostat is all that is required to operate the system CTK01AA W CTK01AA W CTK01AA W CTK01AA W CTK01AA WIRING...

Страница 29: ...fig onfig onfig key again for approximately3secondstoentertheAdvancedInstaller Configurationmenu Clean Display Installer Config Set Time Set Schedule Run Schedule Upon entering the advanced menus the...

Страница 30: ...YES Selecting YES clears the fault history NOTE Consecutively repeated faults are shown a maximum of 3 times DIAGNOSTICS Submenu Item Indication for Display Only not User Modifiable Model Number MOD N...

Страница 31: ...oveinAccessingandNavigat ingtheAdvancedFeaturesMenus NOTE NOTE NOTE NOTE NOTE It is highly recommended that the fault history be cleared when performing maintenance or servicing the furnace N N N N NE...

Страница 32: ...a power up reset x Depress and hold for 2 seconds for an out of box reset Red Communications LED 2 Flashes x Out of box reset x Control power up x Learn button depressed x None x None Off x No power x...

Страница 33: ...t changes the call from low heat tohighheat theintegratedcontrolmodulewillimmediately switch the induced draft blower gas valve and circulator blowertotheirhighstagesettings Ifthetwo stagethermostatch...

Страница 34: ...or near the circulator blowerandmonitorsblowercompartmenttemperatures Theyare a normally closed electrically auto reset sensors These limits guardagainstoverheatingasaresultofinsufficientconditionedai...

Страница 35: ...henreset toprevioussetting NOTE NOTE NOTE NOTE NOTE If the condition which originally caused the lockout still exists the control will return to lockout Refer to the Diagnostic Chart for aid in determ...

Страница 36: ...eel wool Following cleaning the flamesensesignalshouldbeasindicatedintheSpecificationsSheet F F F F FLUE LUE LUE LUE LUE P P P P PASSAGES ASSAGES ASSAGES ASSAGES ASSAGES Q Q Q Q QUALIFIED UALIFIED UAL...

Страница 37: ...per gas pressure or restriction in flue and or combustion air piping front cover pressure switch opening or improper induced draft blower performance x Locate and correct gas interruption x Check fron...

Страница 38: ...ck Furnace message E4 x Flame sensed with no call for heat IMPROPER FLAME E4 x Short to ground in flame sense circuit x Lingering burner flame x Slow closing gas valve x Correct short at flame sensor...

Страница 39: ...y connected wiring x Inspect pressure switch hose Repair replace if necessary x Inspect flue and or inlet air piping for blockage proper length elbows and termination Check drain system Correct as nec...

Страница 40: ...ck Furnace message b1 x Integrated control module has lost communications with circulator blower motor MOTOR COMM b1 x Loose wiring connection at circulator motor control leads x Failed circulator blo...

Страница 41: ...le LED display provides b6 error code x ComfortNet thermostat Call for Service icon illuminated x ComfortNet thermostat scrolls Check Furnace message b6 x Circulator blower motor shuts down for over o...

Страница 42: ...SURE SWITCH STUCK CLOSED AT START OF HEATING CYCLE HIGH STAGE PRESSURE SWITCH STUCK OPEN REVERSED 115 VAC POLARITY DATA NOT YET ON NETWORK INVALID MEMORY CARD DATA BLOWER MOTOR NOT RUNNING BLOWER COMM...

Страница 43: ...Tap B is 10 Tap C 10 Set dip switches 3 and 4 to the appropriate ON OFF positions Speed Selection Dip Switches 390 520 650 780 A B C D 600 800 1000 1200 735 805 875 935 1050 1150 1250 1350 520 715 91...

Страница 44: ...LACEMENT PARTS MUST BE USED WHEN SERVICING ONLY C AIR CLEANER HIGH FIRE PRESS SWTICH INDOOR HUMIDIFIER PK PINK WH 9 IND LO 14 Y2 40 VA 3 HUM YL JUNCTION BLWR PU PURPLE 1 CIRCULATOR BLOW ER R 1 JUNCTIO...

Страница 45: ...INAL WIRE AS SUPPLIED WITH THE FURNACE MUST BE REPLACED IT MUST BE REPLACED WITH WIRING MATERIAL HAVING A TEMPERATURE RATING OF AT LEAST 105 C USE COPPER CONDUCTORS ONLY INTEGRATED CONTROL MODULE RD I...

Страница 46: ...46 THIS PAGE LEFT BLANK INTENTIONALLY...

Страница 47: ...47 THIS PAGE LEFT BLANK INTENTIONALLY...

Страница 48: ...48 Goodman Manufacturing Company L P 5151 San Felipe Suite 500 Houston TX 77056 www goodmanmfg com 2009 2010 Goodman Manufacturing Company L P...

Отзывы: