The wiring harness is an integral part of this furnace. Field alteration
to comply with electrical codes should not be required. Wires are
color coded for identification purposes. Refer to the wiring dia-
gram for wire routings. If any of the original wire as supplied with
the furnace must be replaced, it must be replaced with wiring ma-
terial having a temperature rating of at least 105° C. Any replace-
ment wiring must be a copper conductor.
115 V
115 V
115 V
115 V
115 V
OLT
OLT
OLT
OLT
OLT
L
L
L
L
L
INE
INE
INE
INE
INE
C
C
C
C
C
ONNECTIONS
ONNECTIONS
ONNECTIONS
ONNECTIONS
ONNECTIONS
Before proceeding with electrical connections, ensure that the sup-
ply voltage, frequency, and phase correspond to that specified on
the unit rating plate. Power supply to the furnace must be NEC
Class 1, and must comply with all applicable codes. The furnace
must be electrically grounded in accordance with local codes or, in
their absence, with the latest edition of The National Electric Code,
ANSI NFPA 70 and/or The Canadian Electric Code CSA C22.1.
Use a separate fused branch electrical circuit containing properly
sized wire, and fuse or circuit breaker. The fuse or circuit breaker
must be sized in accordance with the maximum overcurrent pro-
tection specified on the unit rating plate. An electrical disconnect
must be provided at the furnace location.
Connect hot, neutral, and ground wires as shown in the wiring
diagram located on the unit’s blower door.
Line polarity must be observed when making field connections.
Line voltage connections can be made through either the right or
left side panel. The furnace is shipped configured for a right side
electrical connection with the junction box located inside the burner
compartment (blower compartment for downflows). To make elec-
trical connections through the opposite side of the furnace, the
junction box must be relocated to the other side of the burner (or
blower) compartment prior to making electrical connections. To
relocate the junction box, follow the steps shown below.
NOTE:
NOTE:
NOTE:
NOTE:
NOTE: Wire routing must not to interfere with circulator blower
operation, filter removal, or routine maintenance.
JJJJJ
UNCTION
UNCTION
UNCTION
UNCTION
UNCTION
B
B
B
B
B
OX
OX
OX
OX
OX
R
R
R
R
R
ELOCATION
ELOCATION
ELOCATION
ELOCATION
ELOCATION
E
DGES
OF
SHEET
METAL
HOLES
MAY
BE
SHARP
.
U
SE
GLOVES
AS
A
PRECAUTION
WHEN
REMOVING
HOLE
PLUGS
.
WARNING
Line voltage connections can be made through either the right or
left side panel. The furnace is shipped configured for a right side
electrical connection. To make electrical connections through the
opposite side of the furnace, the junction box must be relocated to
the left side prior to making electrical connections. To relocate the
junction box, perform the following steps.
T
O
PREVENT
PERSONAL
INJURY
OR
DEATH
DUE
TO
ELECTRIC
SHOCK
,
DISCONNECT
ELECTRICAL
POWER
BEFORE
INSTALLING
OR
SERVICING
THIS
UNIT
.
WARNING
1. Remove both doors from the furnace.
2. Remove and save the screws holding the junction box to
the right side of the furnace.
3. Models that have the junction box located in the burner or
blower compartment will need to move the junction box
directly over.
4. Attach the junction box to the left side of the furnace, using
the screws removed in step 2.
5. Check the location of the wiring. Confirm that it will not be
damaged by heat from the burners or by the rotation of the
fan. Also confirm that wiring location will not interfere with
filter removal or other maintenance.
After the junction box is in the desired location, use washers to
connect field-supplied conduit to the junction box in accordance
with NEC and local codes. Connect hot, neutral, and ground wires
as shown in the furnace wiring diagram. The wires and ground
screw are located in the furnace junction box.
NOTE:
NOTE:
NOTE:
NOTE:
NOTE: In downflow applications the power leads should be routed
through the supplied wire tabs when locating junction box to the
left side.
Low voltage wires may be connected to the terminal strip.
IMPOR
IMPOR
IMPOR
IMPOR
IMPORT
T
T
T
TANT NO
ANT NO
ANT NO
ANT NO
ANT NOTE:
TE:
TE:
TE:
TE: To avoid possible equipment malfunction, route
the low voltage wires to avoid interference with filter removal or
other maintenance.
HIGH
VOLTAGE
!
T
O
AVOID
THE
RISK
OF
INJURY
,
ELECTRICAL
SHOCK
OR
DEATH
,
THE
FURNACE
MUST
BE
ELECTRICALLY
GROUNDED
IN
ACCORDANCE
WITH
LOCAL
CODES
OR
IN
THEIR
ABSENCE
,
WITH
THE
LATEST
EDITION
OF
THE
N
ATIONAL
E
LECTRIC
C
ODE
.
WARNING
To ensure proper unit grounding, the ground wire should run from
the furnace ground screw located inside the furnace junction box
all the way back to the electrical panel. NOTE:
NOTE:
NOTE:
NOTE:
NOTE: Do not use gas
piping as an electrical ground. To confirm proper unit grounding,
turn off the electrical power and perform the following check.
1. Measure resistance between the neutral (white) connection
and one of the burners.
2. Resistance should measure 10 ohms or less.
This furnace is equipped with a blower door interlock switch which
interrupts unit voltage when the blower door is opened for servic-
ing. Do not defeat this switch.