7. Select the heating speed for your model from the heating
speed chart in the Specification Sheet. The adjust setting
(already established by the cooling speed selection)
determines which set of speeds are available. The selected
speed must provide a temperature rise within the rise range
listed with the particular model.
Example:
Example:
Example:
Example:
Example:
The *MVC80704BX is set for 990 CFM on
cooling, the “ADJUST” is set to “+” (plus). The
four heating speeds available are “A Plus”, “B
Plus”, “C Plus”, and “D Plus”. “A Plus” has a rise
of 38°°°°°F for both stages which is within the
20-50°F rise range for the *MVC80704BX . This
setting will keep electrical consumption to a
minimum. Set the “Heat” speed DIP switches
to “A”.
7
8
A
OFF
OFF
B*
ON
OFF
C
OFF
ON
D
ON
ON
Switch Bank: S4
Heating
Airflow
DIP Switch No.
(*Indicates factory setting)
8. Select the desired “heating” speed tap by positioning
switches 7 and 8 appropriately. Refer to figure above. Verify
CFM by noting the number displayed on the dual 7-segment
LED display.
In general lower heating speeds will: reduce electrical consump-
tion, lower operating sound levels of the blower, and increase the
outlet air temperature delivered to the home. The speeds available
allow the blower performance to be optimized for the particular
homeowner’s needs.
B
B
B
B
B
LOWER
LOWER
LOWER
LOWER
LOWER
H
H
H
H
H
EAT
EAT
EAT
EAT
EAT
O
O
O
O
O
FF
FF
FF
FF
FF
D
D
D
D
D
ELAY
ELAY
ELAY
ELAY
ELAY
T
T
T
T
T
IMINGS
IMINGS
IMINGS
IMINGS
IMINGS
The integrated control module provides a selectable heat off delay
function. The heat off delay period may be set to 90, 120, 150, 180
seconds using the DIP switches or jumper provided on the control
module. The delay is factory shipped at 150 seconds but may be
changed to suit the installation requirements and/or homeowner
preference. Refer to the following figures for switch positions and
corresponding delay times.
1
2
90 seconds
OFF
OFF
120 seconds
ON
OFF
150 seconds *
OFF
ON
180 seconds
ON
ON
Heat OF F Delay
DIP Switch No.
Switch Bank: S1
(*Indic ates factory setting)
Heat Off Delay Dipswitches