![Global Contract Bridges II Скачать руководство пользователя страница 14](http://html1.mh-extra.com/html/global-contract/bridges-ii/bridges-ii_installation-manual_2232713014.webp)
Page
•
globalcontract.com
13
• Summer 2017
GLOBAL
Contract
INSTALLATION GUIDELINES
5
6
Base Feed
Identify type and location of required electric components and position
them in accordance with layout plans.
NOTE: four oblong holes in the Power feed mounting bracket must always
align with four oblong holes in the Power Trough, regardless the Power Trough
mounting bracket position.
Position of the Power Trough mounting brackets (inner or outer set of oblong
holes), is governed by the table leg position:
• outer pair of oblong holes for extended position when the table leg is shared
between two adjacent tables, and
• inner pair of oblong holes when the table leg is tucked under the table, at the
end of a table run.
STEP 1: Secure Power Feed to the Power Trough brackets (ensure that the
liquid tight whip is long enough to reach the power source / fl oor monument).
STEP 2: Lift the Power Trough on one side and rest the Power Feed mounting
bracket on top of the Power Trough brackets.
STEP 3: Lower the Power Trough so that the Power Feed bracket is sandwiched
between the Power Trough and Power Trough supporting brackets; ensure that
threaded studs protrude trough the holes in the Power Trough.
STEP 4: Secure all Power Troughs with supplied nylon thumb nuts.
STEP 5: Connect Power Distribution Housings and Jumper Harnesses on
the ground, just below their future location.
NOTE : There is an arrow and a letter “N” on each Power Distribution Housing
and on every Jumper Harness referring to the correct position in relation to
each other.
STEP 6: Install Duplex Receptacles as illustrated, with circuit numbers in ac-
cordance with the electrical plans.
Note the alignment of the Power feed mounting bracket and Power Trough
oblong holes. Studs on Power Trough brackets point to the inner pair of oblong
holes - indicating tucked in leg application.
Note the alignment of the Power feed mounting bracket and Power Trough
oblong holes. Studs on Power Trough brackets point to the outer pair of oblong
holes - indicating extended, shared leg application.
4
4
3
3
2
2
1
1