46
Fryer Operation
GBF
−
35 / GBF
−
50 Fryers
4.01.11.1 Clearing Controller Errors
&
Alarms
4.02 Cooking
Procedures
The following sections explain
“Best Practice”
procedures for cooking with the
GBF Series Fryer
. Certain
optional
features
are explained where applicable ... your particular equipment
may or may not
have these options installed.
This is a multi
purpose electric fryer for efficiently cooking a variety of menu favorites, from french fries to seafood.
All food products have specific procedures for preparation & cooking, and every food service business has their own
specific standard operating procedures. When preparing, cooking and serving your menu items, please be sure to
follow all of your own
standard practices & guidelines, as they may supercede some of the processes presented in
this manual
..
NOTE: If an error condition persist and cannot be resolved, it could be an indication of component failure or
system malfunction. Please contact a factory
‐
authorized service agent, or call 800.554.4537 for Giles Technical
Support.
NOTE: When an error/alarm is issued and stops a cooking cycle before it is complete, it may become necessary
to discard any food product that was cooking at the time ... always comply with all local Standard Operating
Procedures & Best Practices.
•
OPEN:
DRAIN OPEN
If vat drain valve is opened
(even slightly)
while fryer power is ON
,
alarm sounds,
lower
display screen
reads
OPEn
,
upper display screen
reads
“ERROR ALARM
‐
DRAIN IS OPEN”.
Power to heating
elements is shutdown and remains OFF
until the error is corrected.
Press
[ALARM]
key ... clear alarm by fully closing the drain valve. After closing valve, the alarm sounds again and
upper display screen
reads
“CHECK OIL LEVEL, ENSURE VAT IS FULL, IF FULL THEN PRESS [START]”
.
This is a post
alarm notification, alerting the operator to confirm that cooking oil is still at the
[FULL]
level. Add oil if needed,
then press the
[START]
key to return to
PREHEAT
mode ...
Fryer will not heat until key is pressed.
•
ER03:
LOW OIL LEVEL
Alarm sounds,
lower display
shows
Er03
,
upper display
reads
“ERROR ALARM
‐
CHECK
OIL LEVEL
‐
ENSURE VAT IS FULL”
.
Heating elements are shutdown until the condition is corrected. The detected
differential between a temperature probe at the
[ADD]
level and one attached to a heating element exceeds an
acceptable amount, indicating
low oil level, which greatly increases the potential for a vat fire!
Press the
[ALARM]
key ... allow fryer to cool adequately in order to reset fryer error condition. Add oil to raise level to the
[FULL]
mark, as needed.
•
ER06:
LOW OIL LEVEL Post
error Warning
After
Er03
has been cleared, another alarm sounds. The
lower
display
shows
Er06
,
upper display
reads
“CHECK OIL LEVEL
‐
ENSURE VAT IS FULL
‐
PRESS [START]”
.
This alarm
alerts operator to confirm that cooking oil is at the
[FULL]
level. If situation has been corrected, press
[START]
key to enter
PREHEAT
and proceed to continue cooking operations ...
Fryer will not heat until key is pressed.
•
ER19:
MAX. ELEMENT TEMP
Temperature of heating element has exceeded the
maximum allowed
by the
controller. Alarm sounds,
lower screen
shows
Er19
,
upper screen
reads
“ERROR ALARM
‐
MAX ELEMENT
TEMPERATURE”.
Power to heating elements is shutdown. Press
[ALARM]
key ... elements must cool below the
allowable temperature threshold to clear this error. Typical cause is that the heating element has been exposed
due to low oil level (or no oil). False alarms can occur when preheating
cold oil
at beginning of the day ... regular
stirring of oil while preheating will help avoid such false alarms.
•
ER07:
MAX ELEMENT TEMP Post
Error Warning
After an
Er19
error has been cleared, a secondary notification
alarm occurs. The
lower screen
reads
Er07
,
upper display
reads
“MAX ELEMENT TEMP
‐
PRESS [START]”
.
The
alarm notifies operator that a
maximum element temperature error
has occurred and is now cleared. Press
[START]
key to enter
PREHEAT
mode ...
Fryer will not heat until key is pressed.
During the following steps, instructions indicating to press the
[ALARM]
key are only to silence the audible alarm
tone ... pressing the key
DOES NOT
clear the error. Tone automatically silences after about 10 secs.
Содержание GBF-35
Страница 10: ...4 ...
Страница 22: ...16 Overview GBF 35 GBF 50 Fryers 3 01 Baskets Optional Auto Basket Lifts 2 Hidden 1 4 3 ...
Страница 34: ...28 Overview GBF 35 GBF 50 Fryers Notes ...
Страница 68: ...62 Fryer Operation GBF 35 GBF 50 Fryers ...
Страница 78: ...72 Troubleshooting GBF 50 Fryer ...
Страница 86: ...80 Parts List GBF 35 GBF 50 Fryers 7 05 Control Box Front behind Control Panel 2 5 1 6 4 3 7 8 10 11 ...
Страница 98: ...92 Parts List GBF 35 GBF 50 Fryers 7 11 Fry Vat Assembly 2 3 Top View 1 4 5 Bottom View 7 8 9 10 10 11 12 13 6 ...
Страница 100: ...94 Parts List GBF 35 GBF 50 Fryers 7 12 Filter Pan 3 1 5 4 2 9 7 10 6 8 A ...
Страница 102: ...96 Parts List GBF 35 GBF 50 Fryers Notes ...
Страница 103: ......