45
Fryer Operation
GBF
−
35 / GBF
−
50 Fryers
4.01.11
Controller Errors & Alarms
ERROR CODE DESCRIPTION (OLED Display)
PROBLEM
OPEN
DRAIN IS OPEN
Drain valve is open, or not completely closed. If equipped
w/basket lift, basket will be raised if it is down.
CHECK OIL LEVEL, ENSURE VAT IS
FULL, IF FULL THEN PRESS
[START]
This is a secondary prompt to confirm oil level, which is
displayed after an
OPEN
drain error is cleared.
ER03
LOW OIL LEVEL – ENSURE VAT IS
FULL (Element/Add Level
Differential Warning)
The oil level is below the [ADD] line in the vat. Add fresh oil
until level is at [FULL] mark &
stir. Error remains in effect until
temperature differential is cleared.
ER06
LOW OIL LEVEL – ENSURE VAT IS
FULL – PRESS [START]
(Post ER03 Warning)
This is a secondary prompt to confirm oil level, which is
displayed after
LOW OIL ER03
error is cleared ... fryer wil not
heat until START key is pressed.
ER07
MAX ELEMENT TEMP – PRESS
[START] (Post Warning)
This is a secondary prompt displayed after
MAX
ELEMENT TEMP
ER19
error is cleared (element has cooled sufficiently).
ER13
OIL PROBE Error
Problem with the variable oil temp sensor.
Service required.
ER15
ELEMENT PROBE Error
Problem with the element temp sensor, typically attached
directly to heating element.
Service required.
ER17
ADD LEVEL PROBE Error
Problem with the
“Add Level”
sensor located at vat “ADD” mark.
Fryer without this sensor must have the ELMT
ADD DIFF ENABLE
setting
OFF
in Factory Settings. Sensor cannot be bypassed.
Service required.
ER19
MAX ELEMENT TEMP Error
The maximum heating element temperature has been exceeded.
This is a safety device;
NEVER bypass this probe
.
ER25
GUARD BAND EXCEEDED
Actual oil temperature deviates from setpoint by the Guard
Band value. Allow oil to cool or heat to be within range. Factory
default is 900°F ...
Typically, this error should not occur.
ER37
EEPROM Error
An error occurred while saving settings to the EEPROM.
Contact
Giles Tech Service (800.554.4537).
ER38
Internal ADC Error
The ADC (Analog
to
Digital Converter) chip that reads output
from thermocouples is not working. MCB1 board must be
replaced.
Contact Giles Tech Service (800.554.4537).
When conditions occur that cause unsafe operation or possible damage
to the unit (drain open, low oil level, high temp, etc.), the controller will
halt operation, activate an alarm and display error codes &
messages. Error codes are shown on the
Lower display screen
(red graphic)
... error messages and prompts are shown on the
Upper display screen (blue graphic)
. Generally, power to the
heating elements will be shutdown until an error condition has
been corrected. Pressing the
[ALARM]
key silences the alarm, but
does
not
clear the error. Error codes are shown in the table below and
further details are given in the following section.
Upper
Lower
ALARM
Содержание GBF-35
Страница 10: ...4 ...
Страница 22: ...16 Overview GBF 35 GBF 50 Fryers 3 01 Baskets Optional Auto Basket Lifts 2 Hidden 1 4 3 ...
Страница 34: ...28 Overview GBF 35 GBF 50 Fryers Notes ...
Страница 68: ...62 Fryer Operation GBF 35 GBF 50 Fryers ...
Страница 78: ...72 Troubleshooting GBF 50 Fryer ...
Страница 86: ...80 Parts List GBF 35 GBF 50 Fryers 7 05 Control Box Front behind Control Panel 2 5 1 6 4 3 7 8 10 11 ...
Страница 98: ...92 Parts List GBF 35 GBF 50 Fryers 7 11 Fry Vat Assembly 2 3 Top View 1 4 5 Bottom View 7 8 9 10 10 11 12 13 6 ...
Страница 100: ...94 Parts List GBF 35 GBF 50 Fryers 7 12 Filter Pan 3 1 5 4 2 9 7 10 6 8 A ...
Страница 102: ...96 Parts List GBF 35 GBF 50 Fryers Notes ...
Страница 103: ......