dress, the following message shows up:
DUP. MAC ID TEST
FAILED
In addition to this information, the red LED AL0 starts blinking.
In this case the address of the SBI board must be changed.
If the “Duplicate MAC ID” test is positive, the following message shows up:
DUP. MAC ID TEST
PASSED
This message means that the MAC ID is correct.
During the “Duplicate MAC ID” test, the following message shows up:
DUP. MAC ID TEST
IN PROGRESS - X
X is the current DMC state.
This test takes about two seconds; if the message remains, check cables, con-
nections and Baud Rate. See also the paragraph “Status of Allocation” to display
the Sw Dnet status.
7.7.8 Display Software version (Sotware version)
The Software version of the SBI board is shown.
7.7.9 Display compatibility index(Compatib. index)
The index of compatibility of the Software between the Drive and the SBI board
is shown.