SBI-DN
31
——————
Interface Board DeviceNet
——————
4.1.6.2.2 Read Single Polling S->M Configuration - Reply OK
If the single configuration of the Polling S->M is read correctly, the response is
composed as follows:
DATA TYPE
FIELD
VALUE
MEANING
Byte
Service Code
0Ehex OR
80hex
Get_Attribute_Single Reply
code- Common Service.
Word
Word XX
Polling S->M
XXXX
1)
Drive parameter index assigned
to the Polling S->M XX word.
dn4100
1)
The format of the Drive parameter index is Low Byte - High byte.
4.1.6.2.3 Read Single Polling S->M Configuration - Reply Error
If the reading of the single configuration of the Polling S->M is rejected, the response
is the following:
DATA TYPE
FIELD
VALUE
MEANING
Service
Code
14hex OR
80hex
Get _Attribute_Single Reply
code- Common Service.
1Fhex
Error vendor specific (see
Additional field)
<> 1Fhex
DeviceNet specific error
code (see DeviceNet
Specifications).
Additional
XX
1)
Drive specific error code.
dn4105
Byte
General
Error
1)
For error codes see chapter 6.0.
4.1.6.2.4 Read Entire Polling S->M Configuration
The data frame for the reading of the entire configuration of the Polling S->M is
composed as follows:
DATA TYPE
FIELD
VALUE
MEANING
Byte
Service Code
01hex
Get_Attribute_All -Common
Service.
Class ID
68hex
Polling S->M Configuration
Class Object.
Instance ID
01
Polling S->M Instance ID.
dn4110
See Note
1)
1)
Byte or Word depending on the type of allocation executed by the Master.
4.1.6.2.5 Read Entire Polling S->M Configuration - Reply OK
If the entire configuration of the Polling S->M is read correctly, the response is
composed as follows: