SBI-DN
45
——————
Interface Board DeviceNet
——————
5.1.6.2.6 Read Entire Virtual Digital Input Configuration - Reply Error
If the reading of the entire configuration of the “Virtual Digital Inputs” is rejected,
the response is the following:
DATA TYPE
FIELD
VALUE
MEANING
Service
Code
14hex OR
80hex
Get _Attribute_All Reply code-
Common Service.
1Fhex
Error vendor specific (see
Additional field)
<> 1Fhex
DeviceNet specific error code
(see DeviceNet Specifications).
Additional
XX
1)
Drive specific error code.
dn4130
Byte
General
Error
1)
For error codes see chapter 6.0.
5.2 CONFIGURATION OBJECT VIRTUAL DIGITAL OUTPUT
For the assignment of Drive parameters to the 16 Words of the Virtual Digital Outputs
a new object with a specific identifier class is used.
The object is made as follows:
Class ID: 6Bh.
Class Attribute:
Revision
Instance Attribute:
·
ID = 1: Word for configuration first Output (direction Master ->Slave).
·
ID = 2: Word for configuration second Output (direction Master->Slave).
·
ID = x: Word for configuration Outputs (direction Master->Slave).
·
ID = 16; Word for configuration sixteenth Output (direction Master->Slave).
5.2.1 Class code
Class Code: 6Bhex
5.2.2 Class attributes
Number
Need in
implementation
Access Rule
Name
DeviceNet
Data Type
Description
of Attribute
Semantics of
values
1
Optional
Get
Revision
UINT
Revision of
this object
dn345