www.geehy.com Page 128
Field
Name R/W
Description
When the output compare preload is disabled (OC1PEN=0 for TMRx_CCM1
register), the written value will immediately affect the output compare results;
If the output compare preload is enabled (OC1PEN=1 for TMRx_CCM1
register), the written value will affect the output compare result when an update
event is generated.
Channel 2 capture/compare register (TMRx_CC2)
Offset address: 0x38
Reset value: 0x0000
Field
Name R/W
Description
15:0
CC2
R/W
Capture/Compare Channel 2 Value
Refer to TMRx_CC1
Channel 3 capture/compare register (TMRx_CC3)
Offset address: 0x3C
Reset value: 0x0000
Field
Name R/W
Description
15:0
CC3
R/W
Capture/Compare Channel 3 Value
Refer to TMRx_CC1
Channel 4 capture/compare register (TMRx_CC4)
Offset address: 0x40
Reset value: 0x0000
Field
Name R/W
Description
15:0
CC4
R/W
Capture/Compare Channel 4 Value
Refer to TMRx_CC1
Break and dead-time register (TMRx_BDT)
Offset address: 0x44
Reset value: 0x0000
Note: According to the lock setting, AOEN, BRKPOL, BRKEN, IMOS, RMOS and
DTS[7:0] bits all can be write-protected, and it is necessary to configure them
when writing to TMRx_BDT register for the first time.
Field
Name
R/W
Description
7:0
DTS
R/W
Dead Time Setup
DT is the dead duration, and the relationship between DT and register DTS
is as follows:
DTS[7:5]=0xx=>DT=DTS[7:0]×T
DTS
,
T
DTS
=TDTS
;
DTS[7:5]=10x=>DT=
(
64+DTS[5:0])×T
DTS
,
T
DTS
=2×T
DTS
;
DTS[7:5]=110=>DT=
(
32+DTS[4:0])×T
DTS
,
T
DTS
=8×T
DTS
;
DTS[7:5]=111=>DT=
(
32+DTS[4:0]
)
×T
DTS
,
T
DTS
=16×T
DTS
;
For example: assuming T
DTS
=125ns (8MHZ), the dead time setting is as
follows:
If the step time is 125ns, the dead time can be set from 0 to 15875ns;
If the step time is 250ns, the dead time can be set from 16μs to 31750ns;
If the step time is 1μs, the dead time can be set from 32μs to 63μs;
If the step time is 2μs, the dead time can be set from 64μs to 126μs.