D-4
F60 Feeder Protection System
GE Multilin
D.1 IEC 60870-5-104
APPENDIX D
D
Parameter in control direction
File transfer
Type identifier and cause of transmission assignments
(station-specific parameters)
In the following table:
•Shaded boxes are not required.
•Black boxes are not permitted in this companion standard.
•Blank boxes indicate functions or ASDU not used.
•‘
X
’ if only used in the standard direction
<110> := Parameter of measured value, normalized value
PE_ME_NA_1
<111> := Parameter of measured value, scaled value
PE_ME_NB_1
4
<112> := Parameter of measured value, short floating point value
PE_ME_NC_1
<113> := Parameter activation
PE_AC_NA_1
<120> := File Ready
F_FR_NA_1
<121> := Section Ready
F_SR_NA_1
<122> := Call directory, select file, call file, call section
F_SC_NA_1
<123> := Last section, last segment
F_LS_NA_1
<124> := Ack file, ack section
F_AF_NA_1
<125> := Segment
F_SG_NA_1
<126> := Directory (blank or X, available only in monitor [standard] direction)
C_CD_NA_1
TYPE IDENTIFICATION
CAUSE OF TRANSMISSION
NO.
MNEMONIC
1
2
3
4
5
6
7
8
9
10
11
12
13
20
to
36
37
to
41
44
45
46
47
<1>
M_SP_NA_1
X
X
X
X
X
<2>
M_SP_TA_1
<3>
M_DP_NA_1
<4>
M_DP_TA_1
<5>
M_ST_NA_1
<6>
M_ST_TA_1
<7>
M_BO_NA_1
<8>
M_BO_TA_1
<9>
M_ME_NA_1
PERIODIC, CYC
L
IC
BAC
KGR
O
U
ND SCAN
SPO
NT
AN
EO
US
INIT
IALIZ
E
D
REQUEST O
R
RE
QUESTE
D
ACT
IVATION
ACT
IVATION C
O
NF
IRMAT
ION
DEACT
IVATI
O
N
DEACT
IVATI
O
N C
O
N
F
IRMAT
ION
ACT
IVATION T
E
RMINAT
ION
RETU
RN INF
O
CAUSED BY L
O
CAL C
M
D
FIL
E
TRA
N
SFER
INT
E
R
R
OGA
T
ED BY GROUP <NUMBER
>
REQUEST BY GROU
P
<N> COUN
TER REQ
UNKNO
WN TYPE
IDENTI
FICATION
UNK
NOWN
CAUSE OF T
RANSMISSION
UNKNO
WN
CO
MMON ADDRESS OF ADS
U
UNK
NOWN IN
FORMAT
ION
OBJEC
T
ADDR
UNK
NOWN IN
FORMAT
ION
OBJEC
T
ADDR
Содержание F60 UR Series
Страница 2: ......
Страница 4: ......
Страница 30: ...1 20 F60 Feeder Protection System GE Multilin 1 5 USING THE RELAY 1 GETTING STARTED 1 ...
Страница 48: ...2 18 F60 Feeder Protection System GE Multilin 2 2 SPECIFICATIONS 2 PRODUCT DESCRIPTION 2 ...
Страница 96: ...3 48 F60 Feeder Protection System GE Multilin 3 4 MANAGED ETHERNET SWITCH MODULES 3 HARDWARE 3 ...
Страница 126: ...4 30 F60 Feeder Protection System GE Multilin 4 2 FACEPLATE INTERFACE 4 HUMAN INTERFACES 4 ...
Страница 354: ...5 228 F60 Feeder Protection System GE Multilin 5 9 TESTING 5 SETTINGS 5 ...
Страница 382: ...6 28 F60 Feeder Protection System GE Multilin 6 5 PRODUCT INFORMATION 6 ACTUAL VALUES 6 ...
Страница 398: ...8 8 F60 Feeder Protection System GE Multilin 8 2 FAULT LOCATOR 8 THEORY OF OPERATION 8 ...
Страница 414: ...A 14 F60 Feeder Protection System GE Multilin A 1 PARAMETER LIST APPENDIXA A ...
Страница 492: ...B 78 F60 Feeder Protection System GE Multilin B 4 MEMORY MAPPING APPENDIXB B ...
Страница 530: ...D 10 F60 Feeder Protection System GE Multilin D 1 IEC 60870 5 104 APPENDIXD D ...
Страница 542: ...E 12 F60 Feeder Protection System GE Multilin E 2 DNP POINT LISTS APPENDIXE E ...
Страница 558: ...x F60 Feeder Protection System GE Multilin INDEX ...