GE Multilin
B30 Bus Differential System
B-47
APPENDIX B
B.4 MEMORY MAPPING
B
A315
Digital Counter 1 Reset
0 to 4294967295
---
1
F300
0
A317
Digital Counter 1 Freeze/Reset
0 to 4294967295
---
1
F300
0
A319
Digital Counter 1 Freeze/Count
0 to 4294967295
---
1
F300
0
A31B
Digital Counter 1 Set To Preset
0 to 4294967295
---
1
F300
0
A31D
Reserved (11 items)
---
---
---
F001
0
A328
...Repeated for Digital Counter 2
A350
...Repeated for Digital Counter 3
A378
...Repeated for Digital Counter 4
A3A0
...Repeated for Digital Counter 5
A3C8
...Repeated for Digital Counter 6
A3F0
...Repeated for Digital Counter 7
A418
...Repeated for Digital Counter 8
FlexCurves C and D (Read/Write Setting)
A600
FlexCurve C (120 items)
0 to 65535
ms
1
F011
0
A680
FlexCurve D (120 items)
0 to 65535
ms
1
F011
0
Non Volatile Latches (Read/Write Setting) (16 modules)
A700
Non-Volatile Latch 1 Function
0 to 1
---
1
F102
0 (Disabled)
A701
Non-Volatile Latch 1 Type
0 to 1
---
1
F519
0 (Reset
Dominant)
A702
Non-Volatile Latch 1 Set
0 to 4294967295
---
1
F300
0
A704
Non-Volatile Latch 1 Reset
0 to 4294967295
---
1
F300
0
A706
Non-Volatile Latch 1 Target
0 to 2
---
1
F109
0 (Self-reset)
A707
Non-Volatile Latch 1 Events
0 to 1
---
1
F102
0 (Disabled)
A708
Reserved (4 items)
---
---
---
F001
0
A70C
...Repeated for Non-Volatile Latch 2
A718
...Repeated for Non-Volatile Latch 3
A724
...Repeated for Non-Volatile Latch 4
A730
...Repeated for Non-Volatile Latch 5
A73C
...Repeated for Non-Volatile Latch 6
A748
...Repeated for Non-Volatile Latch 7
A754
...Repeated for Non-Volatile Latch 8
A760
...Repeated for Non-Volatile Latch 9
A76C
...Repeated for Non-Volatile Latch 10
A778
...Repeated for Non-Volatile Latch 11
A784
...Repeated for Non-Volatile Latch 12
A790
...Repeated for Non-Volatile Latch 13
A79C
...Repeated for Non-Volatile Latch 14
A7A8
...Repeated for Non-Volatile Latch 15
A7B4
...Repeated for Non-Volatile Latch 16
IEC 61850 Received Analog Settings (Read/Write Setting) (32 modules)
AA00
IEC 61850 GOOSE Analog 1 Default Value
–1000000 to 1000000
---
0.001
F060
1000
AA02
IEC 61850 GOOSE Analog Input 1 Mode
0 to 1
---
1
F491
0 (Default
Value)
AA03
IEC 61850 GOOSE Analog Input 1 Units
---
---
---
F207
(none)
AA05
IEC 61850 GOOSE Analog Input 1 Per-Unit Base
0 to 999999999.999
---
0.001
F060
1
AA07
...Repeated for IEC 61850 GOOSE Analog Input 2
AA0E
...Repeated for IEC 61850 GOOSE Analog Input 3
AA15
...Repeated for IEC 61850 GOOSE Analog Input 4
AA1C
...Repeated for IEC 61850 GOOSE Analog Input 5
AA23
...Repeated for IEC 61850 GOOSE Analog Input 6
Table B–10: MODBUS MEMORY MAP (Sheet 39 of 60)
ADDR
REGISTER NAME
RANGE
UNITS
STEP
FORMAT
DEFAULT
Содержание B30 UR Series
Страница 10: ...x B30 Bus Differential System GE Multilin TABLE OF CONTENTS ...
Страница 92: ...3 44 B30 Bus Differential System GE Multilin 3 3 DIRECT INPUT AND OUTPUT COMMUNICATIONS 3 HARDWARE ...
Страница 122: ...4 30 B30 Bus Differential System GE Multilin 4 3 FACEPLATE INTERFACE 4 HUMAN INTERFACES 4 ...
Страница 326: ...5 204 B30 Bus Differential System GE Multilin 5 10 TESTING 5 SETTINGS 5 ...
Страница 412: ...A 12 B30 Bus Differential System GE Multilin A 1 PARAMETER LISTS APPENDIX A A ...
Страница 554: ...D 10 B30 Bus Differential System GE Multilin D 1 IEC 60870 5 104 APPENDIX D D ...
Страница 566: ...E 12 B30 Bus Differential System GE Multilin E 2 DNP POINT LISTS APPENDIX E E ...
Страница 574: ...F 8 B30 Bus Differential System GE Multilin F 3 WARRANTY APPENDIX F F ...