GE Multilin
B30 Bus Differential System
B-45
APPENDIX B
B.4 MEMORY MAPPING
B
94FC
...Repeated for Direct Input/Output 22
9508
...Repeated for Direct Input/Output 23
9514
...Repeated for Direct Input/Output 24
9520
...Repeated for Direct Input/Output 25
952C
...Repeated for Direct Input/Output 26
9538
...Repeated for Direct Input/Output 27
9544
...Repeated for Direct Input/Output 28
9550
...Repeated for Direct Input/Output 29
955C
...Repeated for Direct Input/Output 30
9568
...Repeated for Direct Input/Output 31
9574
...Repeated for Direct Input/Output 32
IEC 61850 Received Integers (Read/Write Setting) (16 modules)
98A0
IEC 61850 GOOSE uinteger 1 Default Value
0 to 429496295
---
1
F003
1000
98A2
IEC 61850 GOOSE uinteger Input 1 Mode
0 to 1
---
1
F491
0 (Default
Value)
98A3
...Repeated for IEC61850 GOOSE uinteger 2
98A6
...Repeated for IEC61850 GOOSE uinteger 3
98A9
...Repeated for IEC61850 GOOSE uinteger 4
98AC
...Repeated for IEC61850 GOOSE uinteger 5
98AF
...Repeated for IEC61850 GOOSE uinteger 6
98B2
...Repeated for IEC61850 GOOSE uinteger 7
98B5
...Repeated for IEC61850 GOOSE uinteger 8
98B8
...Repeated for IEC61850 GOOSE uinteger 9
98BB
...Repeated for IEC61850 GOOSE uinteger 10
98BE
...Repeated for IEC61850 GOOSE uinteger 11
98C1
...Repeated for IEC61850 GOOSE uinteger 12
98C4
...Repeated for IEC61850 GOOSE uinteger 13
98C7
...Repeated for IEC61850 GOOSE uinteger 14
98CA
...Repeated for IEC61850 GOOSE uinteger 15
98CD
...Repeated for IEC61850 GOOSE uinteger 16
FlexElement Actual Values (Read Only) (8 modules)
9000
FlexElement 1 Actual
-2147483.647 to
2147483.647
---
0.001
F004
0
9902
FlexElement 2 Actual
-2147483.647 to
2147483.647
---
0.001
F004
0
9904
FlexElement 3 Actual
-2147483.647 to
2147483.647
---
0.001
F004
0
9906
FlexElement 4 Actual
-2147483.647 to
2147483.647
---
0.001
F004
0
9908
FlexElement 5 Actual
-2147483.647 to
2147483.647
---
0.001
F004
0
990A
FlexElement 6 Actual
-2147483.647 to
2147483.647
---
0.001
F004
0
990C
FlexElement 7 Actual
-2147483.647 to
2147483.647
---
0.001
F004
0
990E
FlexElement 8 Actual
-2147483.647 to
2147483.647
---
0.001
F004
0
Teleprotection Inputs/Outputs Commands (Read/Write Command)
9980
Teleprotection Clear Lost Packets
0 to 1
---
1
F126
0 (No)
Teleprotection Inputs/Outputs (Read/Write Settings)
9990
Teleprotection Function
0 to 1
---
1
F102
0 (Disabled)
9991
Teleprotection Number of Terminals
2 to 3
---
1
F001
2
9992
Teleprotection Number of Channels
1 to 2
---
1
F001
1
Table B–10: MODBUS MEMORY MAP (Sheet 37 of 60)
ADDR
REGISTER NAME
RANGE
UNITS
STEP
FORMAT
DEFAULT
Содержание B30 UR Series
Страница 10: ...x B30 Bus Differential System GE Multilin TABLE OF CONTENTS ...
Страница 92: ...3 44 B30 Bus Differential System GE Multilin 3 3 DIRECT INPUT AND OUTPUT COMMUNICATIONS 3 HARDWARE ...
Страница 122: ...4 30 B30 Bus Differential System GE Multilin 4 3 FACEPLATE INTERFACE 4 HUMAN INTERFACES 4 ...
Страница 326: ...5 204 B30 Bus Differential System GE Multilin 5 10 TESTING 5 SETTINGS 5 ...
Страница 412: ...A 12 B30 Bus Differential System GE Multilin A 1 PARAMETER LISTS APPENDIX A A ...
Страница 554: ...D 10 B30 Bus Differential System GE Multilin D 1 IEC 60870 5 104 APPENDIX D D ...
Страница 566: ...E 12 B30 Bus Differential System GE Multilin E 2 DNP POINT LISTS APPENDIX E E ...
Страница 574: ...F 8 B30 Bus Differential System GE Multilin F 3 WARRANTY APPENDIX F F ...