B.4 MEMORY MAPPING
APPENDIX B
B
26FC
IEC 61850 Received uinteger 7
0 to 4294967295
---
1
F003
0
26FE
IEC 61850 Received uinteger 8
0 to 4294967295
---
1
F003
0
2700
IEC 61850 Received uinteger 9
0 to 4294967295
---
1
F003
0
2702
IEC 61850 Received uinteger 10
0 to 4294967295
---
1
F003
0
2704
IEC 61850 Received uinteger 11
0 to 4294967295
---
1
F003
0
2706
IEC 61850 Received uinteger 12
0 to 4294967295
---
1
F003
0
2708
IEC 61850 Received uinteger 13
0 to 4294967295
---
1
F003
0
270A
IEC 61850 Received uinteger 14
0 to 4294967295
---
1
F003
0
270C
IEC 61850 Received uinteger 15
0 to 4294967295
---
1
F003
0
270E
IEC 61850 Received uinteger 16
0 to 4294967295
---
1
F003
0
Expanded FlexStates (Read Only)
2B00
FlexStates, one per register (256 items)
0 to 1
---
1
F108
0 (Off)
Expanded Contact Input/Output States (Read Only)
2D00
Contact Input States, one per register (96 items)
0 to 1
---
1
F108
0 (Off)
2D80
Contact Output States, one per register (64 items)
0 to 1
---
1
F108
0 (Off)
2E00
Virtual Output States, one per register (96 items)
0 to 1
---
1
F108
0 (Off)
Expanded Remote Input/Output Status (Read Only)
2F00
Remote Device States, one per register (32 items) 0 to 1
---
1
F155
0 (Offline)
2F80
Remote Input States, one per register (64 items)
0 to 1
---
1
F108
0 (Off)
Oscillography Values (Read Only)
3000
Oscillography Number of Triggers
0 to 65535
---
1
F001
0
3001
Oscillography Available Records
0 to 65535
---
1
F001
0
3002
Oscillography Last Cleared Date
0 to 400000000
---
1
F050
0
3004
Oscillography Number of Cycles Per Record
0 to 65535
---
1
F001
0
Oscillography Commands (Read/Write Command)
3005
Oscillography Force Trigger
0 to 1
---
1
F126
0 (No)
3011
Oscillography Clear Data
0 to 1
---
1
F126
0 (No)
Oscillography Analog Values (Read Only)
3012
Oscillography Number of Triggers
0 to 32767
---
1
F001
0
User Programmable Fault Report Commands (Read/Write Command)
3060
User Fault Report Clear
0 to 1
---
1
F126
0 (No)
User Programmable Fault Report Actuals (Read Only)
3070
Newest Record Number
0 to 65535
---
1
F001
0
3071
Cleared Date
0 to 4294967295
---
1
F050
0
3073
Report Date (10 items)
0 to 4294967295
---
1
F050
0
User Programmable Fault Report (Read/Write Setting) (2 modules)
3090
Fault Report 1 Fault Trigger
0 to 4294967295
---
1
F300
0
3092
Fault Report 1 Function
0 to 1
---
1
F102
0 (Disabled)
3093
Fault Report 1 Prefault Trigger
0 to 4294967295
---
1
F300
0
3095
Fault Report Analog Channel 1 (32 items)
0 to 65536
---
1
F600
0
30B5
Fault Report 1 Reserved (5 items)
---
---
---
F001
0
30BA
...Repeated for Fault Report 2
Modbus File Transfer (Read/Write)
3100
Name of file to read
---
---
---
F204
(none)
Modbus File Transfer Values (Read Only)
3200
Character position of current block within file
0 to 4294967295
---
1
F003
0
3202
Size of currently-available data block
0 to 65535
---
1
F001
0
3203
Block of data from requested file (122 items)
0 to 65535
---
1
F001
0
Table B–10: MODBUS MEMORY MAP (Sheet 8 of 60)
ADDR
REGISTER NAME
RANGE
UNITS
STEP
FORMAT
DEFAULT
Содержание B30 UR Series
Страница 10: ...x B30 Bus Differential System GE Multilin TABLE OF CONTENTS ...
Страница 92: ...3 44 B30 Bus Differential System GE Multilin 3 3 DIRECT INPUT AND OUTPUT COMMUNICATIONS 3 HARDWARE ...
Страница 122: ...4 30 B30 Bus Differential System GE Multilin 4 3 FACEPLATE INTERFACE 4 HUMAN INTERFACES 4 ...
Страница 326: ...5 204 B30 Bus Differential System GE Multilin 5 10 TESTING 5 SETTINGS 5 ...
Страница 412: ...A 12 B30 Bus Differential System GE Multilin A 1 PARAMETER LISTS APPENDIX A A ...