A.1.1 FLEXANALOG ITEMS
A FlexAnalog parameter is an analog parameter.
FlexAnalog items are also viewable in a web browser. Enter the IP address of the UR, access the
Device Information
Menu
option, then the
FlexAnalog Parameter Listing
option. Entries displayed online depend on order code.
Table A–1: FLEXANALOG DATA ITEMS (Sheet 1 of 10)
ADDRESS
FLEXANALOG NAME
UNITS
DESCRIPTION
5824
Field RTD 1 Value
---
Field RTD 1 value
5825
Field RTD 2 Value
---
Field RTD 2 value
5826
Field RTD 3 Value
---
Field RTD 3 value
5827
Field RTD 4 Value
---
Field RTD 4 value
5828
Field RTD 5 Value
---
Field RTD 5 value
5829
Field RTD 6 Value
---
Field RTD 6 value
5830
Field RTD 7 Value
---
Field RTD 7 value
5831
Field RTD 8 Value
---
Field RTD 8 value
5832
Field TDR 1 Value
---
Field TDR 1 value
5834
Field TDR 2 Value
---
Field TDR 2 value
5836
Field TDR 3 Value
---
Field TDR 3 value
5838
Field TDR 4 Value
---
Field TDR 4 value
5840
Field TDR 5 Value
---
Field TDR 5 value
5842
Field TDR 6 Value
---
Field TDR 6 value
5844
Field TDR 7 Value
---
Field TDR 7 value
5846
Field TDR 8 Value
---
Field TDR 8 value
6144
SRC 1 Ia RMS
Amps
Source 1 phase A current RMS
6146
SRC 1 Ib RMS
Amps
Source 1 phase B current RMS
6148
SRC 1 Ic RMS
Amps
Source 1 phase C current RMS
6150
SRC 1 In RMS
Amps
Source 1 neutral current RMS
6152
SRC 1 Ia Mag
Amps
Source 1 phase A current magnitude
6154
SRC 1 Ia Angle
Degrees
Source 1 phase A current angle
6155
SRC 1 Ib Mag
Amps
Source 1 phase B current magnitude
6157
SRC 1 Ib Angle
Degrees
Source 1 phase B current angle
6158
SRC 1 Ic Mag
Amps
Source 1 phase C current magnitude
6160
SRC 1 Ic Angle
Degrees
Source 1 phase C current angle
6161
SRC 1 In Mag
Amps
Source 1 neutral current magnitude
6163
SRC 1 In Angle
Degrees
Source 1 neutral current angle
6164
SRC 1 Ig RMS
Amps
Source 1 ground current RMS
6166
SRC 1 Ig Mag
Amps
Source 1 ground current magnitude
6168
SRC 1 Ig Angle
Degrees
Source 1 ground current angle
6169
SRC 1 I_0 Mag
Amps
Source 1 zero-sequence current magnitude
6171
SRC 1 I_0 Angle
Degrees
Source 1 zero-sequence current angle
6172
SRC 1 I_1 Mag
Amps
Source 1 positive-sequence current magnitude
6174
SRC 1 I_1 Angle
Degrees
Source 1 positive-sequence current angle
6175
SRC 1 I_2 Mag
Amps
Source 1 negative-sequence current magnitude
6177
SRC 1 I_2 Angle
Degrees
Source 1 negative-sequence current angle
6178
SRC 1 Igd Mag
Amps
Source 1 differential ground current magnitude
6180
SRC 1 Igd Angle
Degrees
Source 1 differential ground current angle
6208
SRC 2 Ia RMS
Amps
Source 2 phase A current RMS
6210
SRC 2 Ib RMS
Amps
Source 2 phase B current RMS
Содержание B30 UR Series
Страница 10: ...x B30 Bus Differential System GE Multilin TABLE OF CONTENTS ...
Страница 92: ...3 44 B30 Bus Differential System GE Multilin 3 3 DIRECT INPUT AND OUTPUT COMMUNICATIONS 3 HARDWARE ...
Страница 122: ...4 30 B30 Bus Differential System GE Multilin 4 3 FACEPLATE INTERFACE 4 HUMAN INTERFACES 4 ...
Страница 326: ...5 204 B30 Bus Differential System GE Multilin 5 10 TESTING 5 SETTINGS 5 ...
Страница 412: ...A 12 B30 Bus Differential System GE Multilin A 1 PARAMETER LISTS APPENDIX A A ...
Страница 554: ...D 10 B30 Bus Differential System GE Multilin D 1 IEC 60870 5 104 APPENDIX D D ...
Страница 566: ...E 12 B30 Bus Differential System GE Multilin E 2 DNP POINT LISTS APPENDIX E E ...
Страница 574: ...F 8 B30 Bus Differential System GE Multilin F 3 WARRANTY APPENDIX F F ...