CHAPTER 2: Installation
www.gateway.com
14
Embedded StorView initial setup
If this is the first startup of the Embedded StorView module, you will probably
need to configure the network settings. The Embedded StorView module
supports both DHCP and manual network settings. By default the Embedded
StorView module looks for a DHCP server to obtain an IP address. If one is not
found, StorView searches to determine if an IP address was previously assigned.
If an address was not previously assigned, the system defaults to an IP address
of:
10.1.1.5
for the lower RAID Controller (Controller 0)
10.1.1.6
for the upper RAID Controller (Controller 1)
10.1.1.7
if an error is detected
Subnet Mask is
255.0.0.0
A tool is provided to configure new Embedded StorView modules. From
Windows platforms, you access the tool through the Embedded link on the disc
navigation menu. From Linux platforms, you access the tool through a
command line executable. For more information, see
“Installing on Linux” on page 12
.
When you run the Embedded StorView Setup program, it broadcasts UDP
packets and any Embedded StorView module replies with UDP packets
containing their information. A list of uninitialized systems is displayed.
Uninitialized
systems are those which have not had the default user name and
password changed. If you create a configuration with arrays and logical drives
but you have not changed the login name and password, the system is still be
considered an uninitialized system. During the process of configuring an
Embedded StorView module, you have to enter a
new
password and confirm
that password. The default password is
password
.
The Embedded StorView module is identified by its MAC and IP address. You
want to configure one Embedded StorView module at a time. You can find the
MAC address located on a label affixed to the top of the controller case or by
accessing the VT-100 text-based menu function for Embedded StorView Menu
mode and viewing the network settings. Note the specific address of each
controller in multiple controller environments and the location where that
specific controller is installed in the enclosure.
Setting up the Embedded StorView Module in Microsoft Windows
To set up the Embedded StorView Module in Microsoft Windows:
1
Insert the Gateway External Backup CD (EBCD) into your CD drive.
2
When the autorun program automatically starts the navigation menu,
click on the link for the hardware (E-842R) product which you have
installed.
Содержание E-842R
Страница 1: ...USER GUIDE Gateway E 842R StorView Storage Management Application ...
Страница 2: ......
Страница 7: ...CHAPTER 1 1 Introduction Overview Inter server communication License manager ...
Страница 10: ...Chapter 1 Introduction www gateway com 4 ...
Страница 11: ...CHAPTER 2 5 Installation Setup for Microsoft Windows platforms Setup for Linux platforms ...
Страница 44: ...CHAPTER 3 Getting Started www gateway com 38 ...
Страница 76: ...CHAPTER 5 SAN LUN Mapping www gateway com 70 ...
Страница 77: ...CHAPTER 6 71 ControllerInformation Controller environmentals Controller advanced settings ...
Страница 86: ...CHAPTER 6 Controller Information www gateway com 80 ...
Страница 104: ...CHAPTER 7 Managing the Storage Solution www gateway com 98 ...
Страница 110: ...CHAPTER 8 Failover Performance and Additional Functions www gateway com 104 ...
Страница 120: ...APPENDIX A Troubleshooting and Support www gateway com 114 ...
Страница 144: ...APPENDIX B Event Logs www gateway com 138 ...
Страница 152: ...APPENDIX C Statistics www gateway com 146 ...
Страница 158: ...APPENDIX D Optimizing RAID 5 Write Performance www gateway com 152 ...
Страница 162: ...Index www gateway com 156 ...
Страница 163: ......
Страница 164: ...A MAN E 842R SW USR GDE R0 09 06 ...