![Gateway E-842R Скачать руководство пользователя страница 134](http://html1.mh-extra.com/html/gateway/e-842r/e-842r_user-manual_569389134.webp)
APPENDIX B: Event Logs
www.gateway.com
128
The controller has started
updating a drive’s firmware.
Drive w/SN (SAS: w/WWN)
<
xxxxxx
> (Slot <
nn
>
ID:<
zz>
Firmware Version:
<
yy.yy.yyyy
).
Information
[0xB66
(2918)]
The controller has
started updating a
drive's firmware. Drive
<w/sn or w/wwn>, Slot
<
nn
>, Enclosure <
nn
>,
Firmware
Version:<
xxxx
>.
No action necessary.
The controller has finished
updating a drive’s firmware.
Drive SN: (SAS: w/WWN) <
xx
xx xx xx xx xx>
ID:<
zz>
(Slot
<
number
>) Firmware
Version: <
yy.yy.yyyy
).
Information
[0xB67
(2919)]
The controller has
finished updating a
drive's firmware. Drive
w/SN or WWN <
xxx
>,
Slot <
nn
>, Enclosure
<
nn
>, Firmware
Version:<
xxxx
>.
No action necessary.
An array expansion has
started on Array <
name
>.
Information
[0xB68
(2920)]
Expansion has started.
No action necessary.
An array expansion has
completed on Array
<
name
>.
Information
[0xB69
(2921)]
Expansion has
completed.
No action necessary.
An array expansion has
restarted on Array <
name
>.
Information
[0xB6A
(2922)]
Expansion has
restarted.
No action necessary.
The writeback cache on
Array <
name
> has been
disabled. Reason(s): <
see
causes
>.
Warning
[0xB6F
(2927)]
Disabling of writeback
cache for the indicated
reasons:
■
The partner
controller has failed.
■
The battery is not
charged or present.
■
The array has
become critical.
■
A
prepare for
shutdown
was
received by the
controller.
■
Replace the failed
controller.
■
Charge the backup
battery or re-install
the battery.
■
Resolve the array
issue and rebuild the
array.
■
No action necessary.
The writeback cache on
Array <
name
> has been
re-enabled.
Information
[0xB70
(2928)]
Re-enabling of
writeback cache.
No action necessary.
Because of a background
verify failure, data blocks at
LBA <yyy> from drive SN:
(SAS: w/WWN) <
xx xx xx xx
xx xx>
(Slot <
number
>) have
been reallocated.
Warning
[0xB71
(2929)]
Data Blocks at LBA
<
yyy
> on Drive w/ SN
(SAS: w/ WWN) <
xx xx
>
(Slot <
nn
>, Enclosure
<
nn
>) have been
reallocated.
No action necessary.
A rebuild was aborted on
(Array <
yy
> Drive <
ww
>).
Information
[0xB73
(2931)]
A rebuild was canceled
by the user.
No action necessary.
(SATA Drives Only)
SATA Drive Error: (Slot
<
number
>) Information
<description>.
Error
[0xB75
(2933)]
Drive or SATA link error.
No action necessary.
Drive & Array Event
Messages
Type [ID]
Cause
Action
Содержание E-842R
Страница 1: ...USER GUIDE Gateway E 842R StorView Storage Management Application ...
Страница 2: ......
Страница 7: ...CHAPTER 1 1 Introduction Overview Inter server communication License manager ...
Страница 10: ...Chapter 1 Introduction www gateway com 4 ...
Страница 11: ...CHAPTER 2 5 Installation Setup for Microsoft Windows platforms Setup for Linux platforms ...
Страница 44: ...CHAPTER 3 Getting Started www gateway com 38 ...
Страница 76: ...CHAPTER 5 SAN LUN Mapping www gateway com 70 ...
Страница 77: ...CHAPTER 6 71 ControllerInformation Controller environmentals Controller advanced settings ...
Страница 86: ...CHAPTER 6 Controller Information www gateway com 80 ...
Страница 104: ...CHAPTER 7 Managing the Storage Solution www gateway com 98 ...
Страница 110: ...CHAPTER 8 Failover Performance and Additional Functions www gateway com 104 ...
Страница 120: ...APPENDIX A Troubleshooting and Support www gateway com 114 ...
Страница 144: ...APPENDIX B Event Logs www gateway com 138 ...
Страница 152: ...APPENDIX C Statistics www gateway com 146 ...
Страница 158: ...APPENDIX D Optimizing RAID 5 Write Performance www gateway com 152 ...
Страница 162: ...Index www gateway com 156 ...
Страница 163: ......
Страница 164: ...A MAN E 842R SW USR GDE R0 09 06 ...