APPENDIX A: Troubleshooting and Support
www.gateway.com
106
Troubleshooting
Problems you may encounter
This appendix provides typical solutions for problems you may encounter while
using StorView to control and manage the storage systems. Also see
, and review the cause and actions for each event listed.
Symptom
Reason
Solution
Continuous
indications that the
partner controller
has failed or is
missing.
A partner controller in an
Active-Active configuration has
failed or was removed.
Operating in a Stand-Alone
configuration with Single
Controller Mode not selected.
Until the partner controller is
replaced, temporarily enable Single
Controller Mode in the
Controller
Parameters
tab. Make sure that
you disable this option when the
partner controller is replaced.
If you are operating in a
Stand-Alone configuration, enable
the Single Controller Mode setting
in the
Controller Parameters
tab.
Password Error
Password not accepted at log in.
Password was forgotten or lost.
The Password is case sensitive.
Make sure that you enter the
password correctly.
Contact Customer Care for the
procedures to recover from a lost or
missing password.
Lost communication
with the RAID
controllers.
Service is hung (Windows).
Restart the StorView service. Access
the Control Panel and double-click
on
Services
. Locate the StorView
Service and click
Stop
. After the
service has stopped, click
Start
then click
RESCAN
on the StorView
Main
window.
Service is hung (Linux).
On Linux systems, access the
process viewer and stop the
StorView Process. Restart the
process and click
RESCAN
on the
StorView
Main
window.
The Hot spare is not
automatically
starting when a
drive failure occurs
in a redundant array
in which a global or
dedicated hot spare
is defined.
The Auto Rebuild option is not
enabled in the Controller
Parameters.
Hot spare disk drive is too small
to be used for the drive
replacement.
Waiting for a valid replacement
drive to be inserted.
Open the
CONTROLLER
window
(click the
Controller
icon), click the
check box on the
Auto Rebuild
parameter.
Make sure that the disk drive
defined as a hot spare is equal to or
greater in size than the drive
members of the arrays.
Auto Rebuild
is not selected and
no hot spare drive is assigned, but
Auto Hot Spare
is enabled. The
array begins rebuilding after a valid
replacement drive is inserted in the
drive slot of the failed drive.
Содержание E-842R
Страница 1: ...USER GUIDE Gateway E 842R StorView Storage Management Application ...
Страница 2: ......
Страница 7: ...CHAPTER 1 1 Introduction Overview Inter server communication License manager ...
Страница 10: ...Chapter 1 Introduction www gateway com 4 ...
Страница 11: ...CHAPTER 2 5 Installation Setup for Microsoft Windows platforms Setup for Linux platforms ...
Страница 44: ...CHAPTER 3 Getting Started www gateway com 38 ...
Страница 76: ...CHAPTER 5 SAN LUN Mapping www gateway com 70 ...
Страница 77: ...CHAPTER 6 71 ControllerInformation Controller environmentals Controller advanced settings ...
Страница 86: ...CHAPTER 6 Controller Information www gateway com 80 ...
Страница 104: ...CHAPTER 7 Managing the Storage Solution www gateway com 98 ...
Страница 110: ...CHAPTER 8 Failover Performance and Additional Functions www gateway com 104 ...
Страница 120: ...APPENDIX A Troubleshooting and Support www gateway com 114 ...
Страница 144: ...APPENDIX B Event Logs www gateway com 138 ...
Страница 152: ...APPENDIX C Statistics www gateway com 146 ...
Страница 158: ...APPENDIX D Optimizing RAID 5 Write Performance www gateway com 152 ...
Страница 162: ...Index www gateway com 156 ...
Страница 163: ......
Страница 164: ...A MAN E 842R SW USR GDE R0 09 06 ...