LMM for the Kodiak 100
Page 7-49
190-02102-00 Rev.4
10. Press the TNK SEL softkey and turn the inner FMS knob to select RIGHT. Press
ENT.
11. Press the FULL softkey. The cursor will highlight the CALIBRATE? option.
12. Press ENT. If a previous CALIBRATION VALUE exists, a prompt appears
requesting overwrite acknowledgment. If prompted, select YES and press ENT.
An ACTUAL QUANTITY of 1056.87 lb. and a CALIBRATED VALUE will appear in
the CALIBRATION TABLE.
13. Check the CALIBRATED TOTAL indication in the lower right-hand corner. Make
sure it remains at 1056.87 lb. ±1.0 lb.
14. Turn off the cursor by pressing the FMS knob, and turn the outer FMS knob to
select SYSTEM page group. Turn the inner knob to select SYSTEM UPLOAD
page. Press the UPDT CFG softkey. A prompt appears asking to UPDATE
CONFIG MODULE. Select YES and press ENT.
15. After UPDATE CONFIG COMPLETE appears, press the ENT key to select OK.
16. Reset any circuit breakers pulled during the procedure.
17. Turn the master switch to the OFF position.
18. Proceed to the Verification procedure.
7.12.2.4 Verification
1. Turn all three displays on in Configuration mode by pushing and holding the ENT
key on each display while applying power. Release the ENT key after
INITIALIZING SYSTEM appears in the upper left corner of the display.
2. On PFD #1, go to the CAL page group, FUEL TANK CALIBRATION page.
3. Ensure the CURRENT TANK is LEFT.
4. Ensure the FUEL UNITS to are set to POUNDS (LB, LB/HR).
5. Check the CALIBRATION TABLE in the lower right screen. Ensure the CALI-
BRATED VALUE at the top of the table is not -1.72000 (this is the default value).
Ensure the CALIBRATED VALUE at the bottom of the table is not 602.90997. If
these default values are present, the fuel system must be recalibrated.
6. Press the TNK SEL softkey and turn the inner FMS knob to select RIGHT. Press
ENT.
7. Check the CALIBRATION TABLE in the lower right screen. Ensure the CALI-
BRATED VALUE at the top of the table is not -1.72000. Ensure the CALIBRATED
VALUE at the bottom of the table is not 602.90997.
8. Turn the master switch to the OFF position.