LMM for the Kodiak 100
Page 7-47
190-02102-00 Rev.4
7.12.2.2 Empty Calibration
1. Place the aircraft in a 1.0° ± 0.25° nose up and 0° ± 0.1° roll attitude, to simulate
an average level cruise flight attitude.
2. Drain all fuel from each fuel tank. Turn both overhead fuel selector valves to the
OFF position. Fill each wing tank with 3.25 gallons (21.8 lb.) of Jet A fuel.
NOTE
If the G1000 NXi is shut down during fuel handling, the system should be
allowed to stabilize for AT LEAST three minutes before proceeding.
CAUTION
If the aircraft is on jacks assure that there is no greater than 50 gallons
(345.0 lbs.) of fuel imbalance between the left and right fuel tanks at any
point during this procedure.
NOTE
A continuous audible tone will sound signaling that both overhead fuel
selector valves are in the OFF position. The NO. 1 and NO. 2 Audio circuit
breakers may be pulled to deactivate the tone. Ensure both circuit breakers
are re-activated after this procedure is completed.
3. Turn all three displays on in Configuration mode by pushing and holding the ENT
key on each display, while applying display power. Release the ENT key after
“INITIALIZING SYSTEM” appears in the upper left corner of the display.
4. On PFD #1, go to the CAL page group, FUEL TANK CALIBRATION page.
5. On PFD #1, enter pass code: softkeys 12, 11, 10, 9 by pressing each softkey
sequentially.
6. Additional softkey labels will appear at the bottom of the display. The system will
default to the LEFT tank.
7. Press the EMPTY softkey. The cursor will highlight the CALIBRATE? option.
8. Press ENT. If a previous CALIBRATION VALUE exists, a prompt will appear
requesting overwrite acknowledgment. If prompted, select YES and press ENT.
An ACTUAL QUANTITY of 0.00 lb. and a CALIBRATED VALUE will appear in the
CALIBRATION TABLE.
9. Check the CALIBRATED TOTAL indication in the lower right-hand corner. Make
sure it remains at 0.00 lb. ±1.0 lb.
10. Press the TNK SEL softkey and turn the inner FMS knob to select RIGHT. Press
ENT.
11. Press the EMPTY softkey. The cursor will highlight the CALIBRATE? option.