______________________________________________________________________________
____________________________________________________________________________
Page 4-44
LMM for the Kodiak 100
190-02102-00 Rev.4
GIA1 COOLING
GIA1 has exceeded its
operating temperature
range.
• Check the fan, wiring, and
air tubing (if applicable).
• Replace the cooling fan if
not sure it is operating
properly.
• If the problem persists,
replace the GIA.
• If the problem persists,
contact Garmin Aviation
Support for assistance.
GIA 1 INOP - CRNT
Check GIA1 Current.
• Aircraft supply voltage to
the GIA 64W.
• Wiring.
GIA 1 INOP - SERL
(COM)
Internal GIA Serial
Communication Fault
(COM Transceiver).
• Cycle power to the GIA.
• Check aircraft supply
voltage to the GIA.
• Check supply voltage(s) at
GIA Main power supply
inputs. The minimum
operational voltage is 9
VDC.
• Replace the GIA 64.
GIA 1 INOP - SERL
(GPS)
Internal GIA Serial
Communication Fault
(GPS Receiver).
• Cycle power to the GIA.
• Check aircraft supply
voltage to the GIA.
• Check supply voltage(s) at
GIA Main power supply
inputs. The minimum
operational voltage is 9
VDC.
• Replace the GIA 64.
GIA 1 INOP - SERL
(NAV)
Internal GIA Serial
Communication Fault
(VOR/ILS Receivers).
• Cycle power to the GIA.
• Check aircraft supply
voltage to the GIA.
• Check supply voltage(s) at
GIA Main power supply
inputs. The minimum
operational voltage is 9
VDC.
• Replace the GIA 64.
Table 4-5. GIA 64W System Messages (Continued)
System Message
Cause
Recommended Actions