______________________________________________________________________________
____________________________________________________________________________
LMM for the Kodiak 100
Page 4-67
190-02102-00 Rev.4
4.7.7 GWX Processor Troubleshooting
Figure 4-13.
WARNING
SAFE DISTANCE DETERMINATION - THE FOLLOWING INFORMATION
ESTABLISHES A MINIMUM SAFE DISTANCE FROM THE ANTENNA
FOR PERSONNEL NEAR AN OPERATING AIRBORNE WEATHER
RADAR. THE MINIMUM SAFE DISTANCE IS BASED UPON THE FCC
EXPOSURE LIMIT AT 9.3 TO 9.5 GHZ FOR GENERAL POPULATION/
UNCONTROLLED ENVIRONMENTS WHICH IS 10 MW/CM2. SEE ADVI-
SORY CIRCULAR 20-68B FOR MORE INFORMATION ON SAFE DIS-
TANCE DETERMINATION. THE GWX PROCESSOR SAFE DISTANCE
DETERMINATION GIVEN IN
SURE LIMITS OF 1 MW/CM2 THAN WHAT IS SPECIFIED IN AC 20-68B.
Table 4-9. Safe Distance Determination
Antenna Size Safe Distance
10”
7.4 ft
12”
9.6 ft
18”
14 ft